The insertion torque-depth curve integral as a measure of implant primary stability: An in vitro study on polyurethane foam blocks.

机构信息

Adjunct Professor, Dental School, Vita-Salute University and IRCCS San Raffaele, Milan, Italy.

Private practice, Vimercate, Italy.

出版信息

J Prosthet Dent. 2018 Nov;120(5):706-714. doi: 10.1016/j.prosdent.2017.04.012. Epub 2017 Jul 8.

Abstract

STATEMENT OF PROBLEM

Recent research has shown that dynamic parameters correlate with insertion energy-that is, the total work needed to place an implant into its site-might convey more reliable information concerning immediate implant primary stability at insertion than the commonly used insertion torque (IT), the reverse torque (RT), or the implant stability quotient (ISQ). Yet knowledge on these dynamic parameters is still limited.

PURPOSE

The purpose of this in vitro study was to evaluate whether an energy-related parameter, the torque-depth curve integral (I), could be a reliable measure of primary stability. This was done by assessing if (I) measurement was operator-independent, by investigating its correlation with other known primary stability parameters (IT, RT, or ISQ) by quantifying the (I) average error and correlating (I), IT, RT, and ISQ variations with bone density.

MATERIAL AND METHODS

Five operators placed 200 implants in polyurethane foam blocks of different densities using a micromotor that calculated the (I) during implant placement. Primary implant stability was assessed by measuring the ISQ, IT, and RT. ANOVA tests were used to evaluate whether measurements were operator independent (P>.05 in all cases). A correlation analysis was performed between (I) and IT, ISQ, and RT. The (I) average error was calculated and compared with that of the other parameters by ANOVA. (I)-density, IT-density, ISQ-density, and RT-density plots were drawn, and their slopes were compared by ANCOVA.

RESULTS

The (I) measurements were operator independent and correlated with IT, ISQ, and RT. The average error of these parameters was not significantly different (P>.05 in all cases). The (I)-density, IT-density, ISQ-density, and RT-density curves were linear in the 0.16 to 0.49 g/cm³ range, with the (I)-density curves having a significantly greater slope than those regarding the other parameters (P≤.001 in all cases).

CONCLUSIONS

The torque-depth curve integral (I) provides a reliable assessment of primary stability and shows a greater sensitivity to density variations than other known primary stability parameters.

摘要

问题陈述

最近的研究表明,动态参数与植入物的插入能量相关,即植入物进入其位置所需的总功,可能比常用的插入扭矩(IT)、反转扭矩(RT)或种植体稳定性指数(ISQ)更能可靠地提供关于植入物初始稳定性的信息。然而,人们对这些动态参数的了解仍然有限。

目的

本体外研究的目的是评估与能量相关的参数,即转矩-深度曲线积分(I),是否可以作为初始稳定性的可靠测量指标。通过评估测量是否不受操作人员影响,以及通过量化(I)平均误差并将(I)、IT、RT 和 ISQ 变化与骨密度相关联来研究其与其他已知初始稳定性参数(IT、RT 或 ISQ)的相关性,来实现这一目的。

材料和方法

5 名操作人员使用微电机在不同密度的聚氨酯泡沫块中植入 200 个种植体,微电机在植入过程中计算(I)。通过测量 ISQ、IT 和 RT 来评估种植体的初始稳定性。采用方差分析(ANOVA)检验来评估测量是否不受操作人员影响(所有情况下 P>.05)。对(I)与 IT、ISQ 和 RT 进行相关性分析。通过 ANOVA 比较(I)平均误差与其他参数的差异。绘制(I)-密度、IT-密度、ISQ-密度和 RT-密度图,并通过协方差分析(ANCOVA)比较其斜率。

结果

(I)测量不受操作人员影响,与 IT、ISQ 和 RT 相关。这些参数的平均误差没有显著差异(所有情况下 P>.05)。(I)-密度、IT-密度、ISQ-密度和 RT-密度曲线在 0.16 至 0.49 g/cm³范围内呈线性,(I)-密度曲线的斜率明显大于其他参数(所有情况下 P≤.001)。

结论

转矩-深度曲线积分(I)提供了对初始稳定性的可靠评估,并显示出比其他已知初始稳定性参数对密度变化更高的敏感性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验