Suppr超能文献

高度近视患者行 toric 与非 toric 可植入式 Collamer 透镜 V4c 植入术后眼前节光学相干断层扫描的前房角和房水深度分析。

Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia.

机构信息

Department of Cornea and Refractive Surgery, Instituto de Oftalmologia 'Conde de Valenciana', Mexico City, Mexico.

出版信息

Br J Ophthalmol. 2018 Apr;102(4):544-548. doi: 10.1136/bjophthalmol-2017-310518. Epub 2017 Jul 20.

Abstract

OBJECTIVE

To assess anterior segment changes, including iridocorneal angle and vault, after toric and non-toric implantable collamer lens (ICL) V4c (STAAR Surgical AG) implantation under different lighting conditions.

METHODS

Longitudinal, prospective, case series. Patients with high myopia (>6 dioptres) underwent toric and non-toric ICL V4c implantation. Optical coherence tomography measurements were taken under different lighting conditions preoperatively and at 1 week and 1, 6 and 12 months of follow-up.

RESULTS

Seventy-six eyes of 42 patients underwent ICL V4c implantation. Mean age was 27.4 years (±5.14 years, range 20 to 39 years). The average iridocorneal angle showed a statistically significant decrease (p<0.05) in all mesopic, scotopic and photopic conditions after 1 week of surgery compared with the preoperative measurements; in mesopic conditions, it decreased 14.1°, in photopic conditions 14.8° and scotopic conditions 13.2°. The angle measurement had a statistically significant change only in mesopic conditions (p=0.01) over the 1-year follow-up. The average vault under mesopic conditions was 0.661±0.21 mm at week 1. The vault measurement change was statistically significant over the 1-year follow-up in mesopic conditions (p=0.01). Refractive results showed a significant improvement in both uncorrected and corrected distance visual acuity (p<0.001).

CONCLUSION

There is a significant reduction in the iridocorneal angle after ICL V4c implantation. Furthermore, there is a change under mesopic conditions in both the iridocorneal angle and vault during long-term follow-up.

摘要

目的

评估在不同照明条件下,植入 Toric 和非 Toric 可折叠 Collamer 透镜(STAAR Surgical AG 的 ICL V4c)后眼前节的变化,包括虹膜角膜角和拱高。

方法

前瞻性、纵向、病例系列研究。高度近视(>6 屈光度)患者接受 Toric 和非 Toric ICL V4c 植入。在术前和术后 1 周、1、6 和 12 个月进行不同照明条件下的光学相干断层扫描测量。

结果

42 例患者的 76 只眼接受了 ICL V4c 植入。平均年龄为 27.4 岁(±5.14 岁,范围 20 至 39 岁)。与术前测量相比,所有中光、暗光和高光条件下,术后 1 周平均虹膜角膜角均有统计学意义的下降(p<0.05);在中光条件下下降 14.1°,在高光条件下下降 14.8°,在暗光条件下下降 13.2°。在 1 年的随访中,只有在中光条件下,角度测量才有统计学意义的变化(p=0.01)。在中光条件下,术后第 1 周平均拱高为 0.661±0.21mm。在中光条件下,1 年随访中拱高的变化有统计学意义(p=0.01)。屈光结果显示未矫正和矫正远视力均有显著改善(p<0.001)。

结论

植入 ICL V4c 后虹膜角膜角明显减小。此外,在长期随访中,中光条件下角膜虹膜角和拱高均有变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验