Suppr超能文献

在平均 12 年的随访中,与传统聚乙烯相比,高交联聚乙烯可降低骨溶解发生率和无水泥全髋关节置换术后与磨损相关的再手术率。

Highly Cross-Linked Polyethylene Reduces Osteolysis Incidence and Wear-Related Reoperation Rate in Cementless Total Hip Arthroplasty Compared With Conventional Polyethylene at a Mean 12-Year Follow-Up.

机构信息

Department of Orthopaedic Surgery, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.

Department of Orthopaedic Surgery, Moji Medical Center, Kitakyushu, Japan.

出版信息

J Arthroplasty. 2017 Dec;32(12):3771-3776. doi: 10.1016/j.arth.2017.06.047. Epub 2017 Jul 8.

Abstract

BACKGROUND

A number of studies on total hip arthroplasty have compared highly cross-linked polyethylene (HXLPE) with conventional polyethylene (CPE) liners beyond 10 years. However, the impact of HXLPE on the wear-related reoperation rate is unclear. The purpose of this study was to evaluate the clinical advantage of using a single manufacturer's HXLPE in terms of reducing the reoperation rate.

METHODS

The study was a follow-up retrospective cohort study over a mean of 12 years that examined patients aged 45-70 years with cementless total hip arthroplasty using a 26-mm-diameter cobalt-chromium head. Sixty-seven patients (79 hips; HXLPE group = 41 hips, CPE group = 38 hips) were evaluated for a minimum 10-year follow-up. Kaplan-Meier survival analysis was performed, with wear-related reoperations and radiographic osteolysis serving as the end points. The polyethylene wear rate was also assessed.

RESULTS

The mean 12-year follow-up rates of survivorship that were evaluated using wear-related reoperations as the end point were 100% and 91.4% in the HXLPE and CPE groups, respectively (P = .007), and the mean 12-year follow-up rates of survivorship with osteolysis as the end point were 100% and 36.2%, respectively (P < .001). Compared with the CPE group, the HXLPE group presented a significantly reduced wear rate (HXLPE group, 0.035 mm/y; CPE group, 0.118 mm/y).

CONCLUSION

A unique strength of this study is that we assessed a single manufacturer's HXLPE while keeping most other implant parameters uniform. This study reveals the clinical advantage of using a single manufacturer's HXLPE in terms of a reduced wear-related reoperation rate at a mean 12-year follow-up.

摘要

背景

多项全髋关节置换术研究对超过 10 年的高交联聚乙烯(HXLPE)与传统聚乙烯(CPE)衬垫进行了比较。然而,HXLPE 对与磨损相关的再手术率的影响尚不清楚。本研究旨在评估使用单一制造商的 HXLPE 在降低再手术率方面的临床优势。

方法

本研究是一项平均随访 12 年的回顾性队列研究,纳入了年龄在 45-70 岁之间、使用 26 毫米直径钴铬头的非骨水泥全髋关节置换术患者。对 67 例患者(79 髋;HXLPE 组 41 髋,CPE 组 38 髋)进行了至少 10 年的随访。采用 Kaplan-Meier 生存分析,以与磨损相关的再手术和影像学骨溶解为终点。还评估了聚乙烯的磨损率。

结果

以与磨损相关的再手术为终点,12 年的平均随访生存率分别为 HXLPE 组 100%和 CPE 组 91.4%(P=0.007),以骨溶解为终点的 12 年平均随访生存率分别为 100%和 36.2%(P<0.001)。与 CPE 组相比,HXLPE 组的磨损率明显降低(HXLPE 组,0.035 毫米/年;CPE 组,0.118 毫米/年)。

结论

本研究的一个独特优势是评估了单一制造商的 HXLPE,同时保持了大多数其他植入物参数的一致性。本研究揭示了在平均 12 年随访中,使用单一制造商的 HXLPE 可降低与磨损相关的再手术率的临床优势。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验