Intra-oral 3D scanning of dentitions has the potential to provide a fast, accurate and non-invasive method of recording dental information. The aim of this study was to assess the reliability of measurements of human dental casts made using a portable intra-oral 3D scanner appropriate for field use.
Two examiners each measured 84 tooth and 26 arch features of 50 sets of upper and lower human dental casts using digital hand-held callipers, and secondly using the measuring tool provided with the Zfx IntraScan intraoral 3D scanner applied to the virtual dental casts. The measurements were repeated at least one week later. Reliability and validity were quantified concurrently by calculation of intra-class correlation coefficients (ICC) and standard errors of measurement (SEM).
The measurements of the 110 landmark features of human dental casts made using the intra-oral 3D scanner were virtually indistinguishable from measurements of the same features made using conventional hand-held callipers. The difference of means as a percentage of the average of the measurements by each method ranged between 0.030% and 1.134%. The intermethod SEMs ranged between 0.037% and 0.535%, and the inter-method ICCs ranged between 0.904 and 0.999, for both the upper and the lower arches. The inter-rater SEMs were one-half and the intra-method/rater SEMs were one-third of the inter-method values.
This study demonstrates that the Zfx IntraScan intra-oral 3D scanner with its virtual on-screen measuring tool is a reliable and valid method for measuring the key features of dental casts.
牙列的口腔内三维扫描有潜力提供一种快速、准确且无创的记录牙齿信息的方法。本研究的目的是评估使用适用于现场使用的便携式口腔内三维扫描仪对人体牙模进行测量的可靠性。
两名检查者分别使用数字手持卡尺测量50套上下颌人体牙模的84个牙齿和26个牙弓特征,其次使用Zfx IntraScan口腔内三维扫描仪配备的测量工具测量虚拟牙模。至少一周后重复测量。通过计算组内相关系数(ICC)和测量标准误差(SEM)同时对可靠性和有效性进行量化。
使用口腔内三维扫描仪对人体牙模的110个标志特征进行的测量与使用传统手持卡尺对相同特征进行的测量几乎没有区别。每种方法测量平均值的差异占每种方法测量平均值的百分比在0.030%至1.134%之间。上下牙弓的方法间SEM在0.037%至0.535%之间,方法间ICC在0.904至0.999之间。检查者间SEM是方法间值的一半,方法内/检查者内SEM是方法间值的三分之一。
本研究表明,配备虚拟屏幕测量工具的Zfx IntraScan口腔内三维扫描仪是测量牙模关键特征的可靠且有效的方法。