Johnson Chris A, Thapa Suman, George Kong Yu Xiang, Robin Alan L
Department of Ophthalmology and Visual Sciences, University of Iowa Hospitals and Clinics, Iowa City, Iowa.
Nepal Glaucoma Eye Clinic, Tilganga Institute of Ophthalmology, Kathmandu, Nepal.
Am J Ophthalmol. 2017 Oct;182:147-154. doi: 10.1016/j.ajo.2017.08.007. Epub 2017 Aug 25.
To evaluate the accuracy and efficiency of Visual Fields Easy (VFE), a free iPad app, for performing suprathreshold perimetric screening.
Prospective, cross-sectional validation study.
We performed screening visual fields using a calibrated iPad 2 with the VFE application on 206 subjects (411 eyes): 210 normal (NL), 183 glaucoma (GL), and 18 diabetic retinopathy (DR) at Tilganga Institute of Ophthalmology, Kathmandu, Nepal. We correlated the results with a Humphrey Field Analyzer using 24-2 SITA Standard tests on 373 of these eyes (198 NL, 160 GL, 15 DR).
The number of missed locations on the VFE correlated with mean deviation (MD, r = 0.79), pattern standard deviation (PSD, r = 0.60), and number of locations that were worse than the 95% confidence limits for total deviation (r = 0.51) and pattern deviation (r = 0.68) using SITA Standard. iPad suprathreshold perimetry was able to detect most visual field deficits with moderate (MD of -6 to -12 dB) and advanced (MD worse than -12 dB) loss, but had greater difficulty in detecting early (MD better than -6 dB) loss, primarily owing to an elevated false-positive response rate. The average time to perform the Visual Fields Easy test was 3 minutes, 18 seconds (standard deviation = 16.88 seconds).
The Visual Fields Easy test procedure is a portable, fast, effective procedure for detecting moderate and advanced visual field loss. Improvements are currently underway to monitor eye and head tracking during testing, reduce testing time, improve performance, and eliminate the need to touch the video screen surface.
评估一款免费的iPad应用程序Visual Fields Easy(VFE)进行超阈值视野筛查的准确性和效率。
前瞻性横断面验证研究。
我们在尼泊尔加德满都的蒂尔甘加眼科研究所,使用装有VFE应用程序的校准iPad 2对206名受试者(411只眼)进行了视野筛查:210名正常(NL)受试者、183名青光眼(GL)患者和18名糖尿病视网膜病变(DR)患者。我们将其中373只眼(198只NL、160只GL、15只DR)的结果与使用24-2 SITA标准测试的 Humphrey视野分析仪的结果进行了相关性分析。
VFE上遗漏位置的数量与平均偏差(MD,r = 0.79)、模式标准差(PSD,r = 0.60)以及使用SITA标准时总偏差(r = 0.51)和模式偏差(r = 0.68)超过95%置信限的位置数量相关。iPad超阈值视野检查能够检测出大多数中度(MD为-6至-12 dB)和重度(MD低于-12 dB)视野缺损,但在检测早期(MD高于-6 dB)缺损时困难较大,主要原因是假阳性反应率升高。进行Visual Fields Easy测试的平均时间为3分18秒(标准差 = 16.88秒)。
Visual Fields Easy测试程序是一种用于检测中度和重度视野缺损的便携式、快速且有效的程序。目前正在进行改进,以在测试过程中监测眼睛和头部跟踪、减少测试时间、提高性能并消除触摸视频屏幕表面的需求。