L5椎弓根螺钉置入术后腰段节段性动脉假性动脉瘤。一种罕见的血管并发症。

Lumbar segmental artery pseudoaneurysm after L5 pedicle screw placement. A rare vascular complication.

作者信息

Álvarez Postigo M, Pizones Arce J, Izquierdo Núñez E

机构信息

Hospital Universitario de Getafe, Getafe, Madrid, España.

Hospital Universitario La Paz, Madrid, España.

出版信息

Rev Esp Cir Ortop Traumatol. 2017 Nov-Dec;61(6):436-440. doi: 10.1016/j.recot.2017.06.003. Epub 2017 Sep 8.

Abstract

Posterior lumbar screw fixation is a common surgical procedure nowadays. However, it can sometimes produce complications that can be devastating. One of the less common causes of major complication is the misplacement of a pedicle screw. This highlights the importance of being methodical when placing pedicle screws, and checking that the pathway has been created correctly and their placement. We present a case of a massive bleed after a pedicular screw placement during lumbar canal stenosis surgery. Screw malposition led to intraoperative haemodynamic instability after failed attempts to control bleeding in the surgical site. Contrast enhanced CT imaging revealed a lumbar intersegmentary artery injury that was eventually controlled by means of a coil embolisation.

摘要

腰椎后路螺钉固定术是目前一种常见的外科手术。然而,它有时会产生极具破坏性的并发症。主要并发症的较不常见原因之一是椎弓根螺钉置入不当。这凸显了在置入椎弓根螺钉时有条不紊的重要性,并要检查通道是否正确建立以及螺钉的位置。我们报告一例腰椎管狭窄症手术中椎弓根螺钉置入后大量出血的病例。螺钉位置不当导致在手术部位控制出血失败后术中血流动力学不稳定。对比增强CT成像显示一条腰段节段间动脉损伤,最终通过弹簧圈栓塞得以控制。