Suppr超能文献

巩膜接触镜拱高对视力和舒适度的影响。

The Impact of Scleral Contact Lens Vault on Visual Acuity and Comfort.

作者信息

Otchere Heinz, Jones Lyndon, Sorbara Luigina

机构信息

School of Optometry & Vision Science (H.O., L.J., L.S.), Centre for Contact Lens Research, University of Waterloo, Waterloo, ON, Canada.

出版信息

Eye Contact Lens. 2018 Nov;44 Suppl 2:S54-S59. doi: 10.1097/ICL.0000000000000427.

Abstract

PURPOSE

To assess how varying degrees of corneal clearance of scleral contact lenses (ScCL) impact visual acuity (VA) and comfort in patients with corneal ectasia.

METHOD

Three ScCL were fitted to 20 subjects with previous diagnosis of either keratoconus (n=18) or pellucid marginal degeneration (n=2). Fitting of ScCL was based on corneal sagittal height (CSH) measured with Visante OCT at a 15-mm chord on the horizontal meridian. To select the ScCL from the diagnostic lens set, values of 325, 375, and 425 μm were randomly added in sequence to CSH. Subjects wore ScCL for 1 hr. Central corneal clearance (CCC) and topographic corneal clearance (TCC) along the vertical meridian were assessed using an ultralong optical coherence tomographer. High-contrast VA (HCVA) and low-contrast VA (LCVA) were measured using a logarithm of the minimum angle of resolution VA chart, and comfort ratings were obtained with a standard comfort scale (0-100).

RESULTS

Mean CSH in the horizontal meridian was 3.78±0.53 (range: 3.33-4.17) mm at a 15-mm chord. Mean CCC was 190±100 μm (TCC: 160±94 μm at +3 mm and 180±94 μm at -3 mm), 360±120 μm (TCC: 260±100 μm at +3 mm and 330±110 μm at -3 mm), and 450±170 μm (TCC: 320±120 μm at +3 mm and 400±120 μm at -3 mm) for each lens (P=0.001). Mean HCVA for lenses 1, 2, and 3 were 0.05±0.12, 0.07±0.11, and 0.11±0.08 respectively, which were significantly different (P=0.02). Tukey post hoc analysis showed that this difference was only significant between lenses 1 and 3 (P=0.01). Similar findings were found for LCVA. Comfort ratings for lenses 1, 2, and 3 were 74.9±9.2, 79.7±11.6, and 78.6±10.8, respectively (P=0.24).

CONCLUSION

The CSH is an effective method of determining the appropriate lens/cornea relationship. Lens 2 (+375 μm) gave the best combination of acuity and comfort ratings. Evaluation of the fluorescein pattern must be balanced with VA and comfort ratings for successful fitting in a clinical setting.

摘要

目的

评估巩膜接触镜(ScCL)不同程度的角膜间隙对圆锥角膜患者视力(VA)和舒适度的影响。

方法

为20例先前诊断为圆锥角膜(n = 18)或透明边缘变性(n = 2)的受试者佩戴3种ScCL。ScCL的验配基于用Visante OCT在水平子午线上15 mm弦长处测量的角膜矢高(CSH)。为从诊断镜片组中选择ScCL,依次随机给CSH加上325、375和425μm的值。受试者佩戴ScCL 1小时。使用超长光学相干断层扫描仪评估垂直子午线上的中央角膜间隙(CCC)和地形图角膜间隙(TCC)。使用最小分辨角视力表的对数测量高对比度视力(HCVA)和低对比度视力(LCVA),并通过标准舒适度量表(0 - 100)获得舒适度评分。

结果

在15 mm弦长处,水平子午线上的平均CSH为3.78±0.53(范围:3.33 - 4.17)mm。每种镜片的平均CCC分别为190±100μm(TCC:在+3 mm处为160±94μm,在 - 3 mm处为180±94μm)、360±120μm(TCC:在+3 mm处为260±100μm,在 - 3 mm处为330±110μm)和450±170μm(TCC:在+3 mm处为320±120μm,在 - 3 mm处为400±120μm)(P = 0.001)。镜片1、2和3的平均HCVA分别为0.05±0.12、0.07±0.11和0.11±0.08,差异有统计学意义(P = 0.02)。Tukey事后分析表明,这种差异仅在镜片1和3之间有统计学意义(P = 0.01)。LCVA也有类似发现。镜片1、2和3的舒适度评分分别为74.9±9.2、79.7±11.6和78.6±10.8(P = 0.24)。

结论

CSH是确定合适的镜片/角膜关系的有效方法。镜片2(+375μm)在视力和舒适度评分方面给出了最佳组合。在临床环境中成功验配时,荧光素图案的评估必须与视力和舒适度评分相平衡。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验