义齿清洁剂对热固化义齿基托树脂表面粗糙度和挠曲强度的影响——一项体外研究

Effect of Denture Cleansers on Surface Roughness and Flexural Strength of Heat Cure Denture Base Resin-An In vitro Study.

作者信息

Sharma Prabal, Garg Sandeep, Kalra Nidhi Mangtani

机构信息

Postgraduate Student, Department of Prosthodontics, MM College of Dental Sciences and Research, Mullana, Ambala, Haryana, India.

Professor, Department of Prosthodontics, MM College of Dental Sciences and Research, Mullana, Ambala, Haryana, India.

出版信息

J Clin Diagn Res. 2017 Aug;11(8):ZC94-ZC97. doi: 10.7860/JCDR/2017/27307.10483. Epub 2017 Aug 1.

Abstract

INTRODUCTION

Denture cleansing is essential for maintaining the prosthesis and oral health, so choosing an appropriate cleanser which is not only efficient but also not adversely affects the properties of denture base resin itself with prolonged use is important. Hence, the present study was undertaken.

AIM

To evaluate the effect of different chemical cleansers on surface roughness and flexural strength of heat cure denture base resin when used daily for three months.

MATERIALS AND METHODS

A total of 40 rectangular specimens (65 mm x 10 mm x 2.5 mm) and 32 disc shaped specimens (10 mm x 2 mm) were fabricated from heat cure denture base resin (DPI Heat Cure) for evaluation of flexural strength and surface roughness respectively. The specimens not subjected to cleansing served as control whereas other specimens were subjected to daily cleansing with one of the three cleansers (1% sodium hypochlorite, fittydent tablets, 100% vinegar) daily and stored in distilled water for three months. Surface analyser (Surftest SJ-210, Mitutoyo, USA) was used to evaluate change in surface roughness of the specimens (ΔRa) before and after cleansing. Also, flexural strength (S) of specimens after cleansing was evaluated by subjecting the specimens to load of 50 kgf at a crosshead speed of 5 mm/min in universal testing machine (INSTRON). Data obtained by testing was compiled and analysed using statistical software SPSS version 17.5. ANOVA and Post-hoc Tukey's tests were used and p-value <0.05 was considered significant in all tests.

RESULTS

Results showed that the surface roughness of the specimens was significantly increased and flexural strength significantly decreased after immersion in 1% sodium hypochlorite solution for three months (p<0.05). No statistically significant difference were observed in flexural strength and surface roughness of the specimens cleaned with fittydent and 100% vinegar for three months (p>0.05).

CONCLUSION

Within the limitations of this in vitro study, it was concluded that immersion in 1% sodium hypochlorite solutions for three months influences the surface roughness and flexural strength of heat cure denture base resin; hence it should be used with caution when used for long period. Fittydent and 100% vinegar can be recommended as a routine chemical cleansing agent for long term use.

摘要

引言

义齿清洁对于维护假牙和口腔健康至关重要,因此选择一种合适的清洁剂很重要,这种清洁剂不仅要高效,而且长期使用时不会对义齿基托树脂本身的性能产生不利影响。因此,开展了本研究。

目的

评估不同化学清洁剂每日使用三个月时对热固化义齿基托树脂表面粗糙度和弯曲强度的影响。

材料与方法

用热固化义齿基托树脂(DPI热固化型)制作了总共40个矩形试件(65毫米×10毫米×2.5毫米)和32个圆盘形试件(10毫米×2毫米),分别用于评估弯曲强度和表面粗糙度。未进行清洁处理的试件作为对照,而其他试件每天用三种清洁剂之一(1%次氯酸钠、菲蒂登特片、100%醋)进行清洁,并在蒸馏水中保存三个月。使用表面分析仪(Surftest SJ - 210,三丰,美国)评估清洁前后试件表面粗糙度的变化(ΔRa)。此外,通过在万能材料试验机(英斯特朗)中以5毫米/分钟的十字头速度对试件施加50千克力的载荷来评估清洁后试件的弯曲强度(S)。使用统计软件SPSS 17.5对测试获得的数据进行整理和分析。采用方差分析和事后Tukey检验,所有测试中p值<0.05被认为具有显著性。

结果

结果表明,在1%次氯酸钠溶液中浸泡三个月后,试件的表面粗糙度显著增加,弯曲强度显著降低(p<0.05)。用菲蒂登特和100%醋清洁三个月的试件,其弯曲强度和表面粗糙度未观察到统计学上的显著差异(p>0.05)。

结论

在本体外研究的局限性内,得出结论:在1%次氯酸钠溶液中浸泡三个月会影响热固化义齿基托树脂的表面粗糙度和弯曲强度;因此长期使用时应谨慎使用。菲蒂登特和100%醋可推荐作为长期使用的常规化学清洁剂。