Suppr超能文献

用于测定药物制剂、血清和尿液样本中盐酸利多卡因的新型电位传感器的研制

Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples.

作者信息

Ali Tamer Awad, Mohamed Gehad Genidy, Yahya Ghada A

机构信息

Egyptian Petroleum Research Institute (EPRI), 11727, Cairo, Egypt.

Chemistry Department, Faculty of Science, Cairo University, 12613, Giza, Egypt.

出版信息

Iran J Pharm Res. 2017 Spring;16(2):498-512.

Abstract

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations and biological fluids (urine and serum). It was based on potentiometric titration of lidocaine hydrochloride using modified screen-printed and carbon paste electrodes as end point indicator sensors. The influences of the paste composition, different conditioning parameters and foreign ions on the electrodes performance were investigated and response times of the electrodes were studied. The electrodes showed Nernstian response of 58.9 and 57.5 mV decade in the concentration range of 1×10-1×10 and 6.2×10-1×10 mol L for modified screen-printed and carbon paste electrodes, respectively. The electrodes were found to be usable within the pH range of 2.0-8.0 and 2.0-7.5, exhibited a fast response time (about 6 and 4) low detection limit (1×10 and 6.2×10 mol L), long lifetime (6 and 4 months) and good stability for modified screen-printed (Electrode VII) and carbon paste electrodes (Electrode III), respectively. The electrodes were successfully applied for the determination of lidocaine hydrochloride in pure solutions, pharmaceutical preparation and biological fluids (urine and serum) samples. The results obtained applying these potentiometric electrodes were comparable with British pharmacopeia. The method validation parameters were optimized and the method can be applied for routine analysis of lidocaine hydrochloride drug.

摘要

本文着重于盐酸利多卡因作为一种局部麻醉药的测定。描述了一种基于修饰丝网印刷电极和修饰碳糊离子选择性电极的电位分析法,用于测定不同药物制剂以及生物流体(尿液和血清)中的盐酸利多卡因。该方法基于使用修饰丝网印刷电极和碳糊电极作为终点指示传感器对盐酸利多卡因进行电位滴定。研究了糊剂组成、不同的调节参数和外来离子对电极性能的影响,并研究了电极的响应时间。对于修饰丝网印刷电极和碳糊电极,在1×10⁻¹×10和6.2×10⁻¹×10 mol/L的浓度范围内,电极分别显示出58.9和57.5 mV/十倍浓度的能斯特响应。发现修饰丝网印刷电极(电极VII)和碳糊电极(电极III)分别在pH范围2.0 - 8.0和2.0 - 7.5内可用,响应时间快(约6秒和4秒),检测限低(1×10⁻⁶和6.2×10⁻⁷ mol/L),寿命长(6个月和4个月)且稳定性良好。这些电极已成功应用于纯溶液、药物制剂以及生物流体(尿液和血清)样品中盐酸利多卡因的测定。应用这些电位电极获得的结果与英国药典相当。对方法验证参数进行了优化,该方法可用于盐酸利多卡因药物的常规分析。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ce43/5603859/cd3194a27cb2/ijpr-16-498-g001.jpg