Pawar Neelam, Maheshwari Devendra, Ravindran Meenakshi, Ramakrishnan Renagappa
Department of Paediatric Ophthalmology, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.
Department of Glaucoma, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Tirunelveli, Tamil Nadu, India.
Indian J Ophthalmol. 2017 Oct;65(10):955-962. doi: 10.4103/ijo.IJO_71_17.
To determine interocular differences in the retinal nerve fiber layer (RNFL) and optic nerve head (ONH) parameters in a pediatric population using Cirrus high-definition optical coherence tomography (HD-OCT).
Seventy normal Indian children aged 5-17 years presenting to the Pediatric Clinic were included in this observational cross-sectional study. All subjects underwent a comprehensive ophthalmologic examination and an evaluation of the RNFL and ONH by Cirrus HD-OCT. Differences between the right and left eyes were calculated and values were compared by means of a paired t-test. Subjects were also divided into two groups based on age (under or over 10 years of age). Interocular differences in RNFL and ONH parameters together with sex and age variations for these differences were determined.
The mean age of studied pediatric population was 11.83 ± 3.3 years (range 5-17). Average RNFL thickness was 94.46 ± 8.7 μm (± SD) (range 77-111). Differences in the average RNFL between right and left eyes were not statistically significant (P = 0.060). Superior quadrant RNFL was thicker in the left eye and temporal quadrant was thicker in the right eye. Among ONH parameters, there were no statistically significant differences in any parameters, except vertical cup-disc (CD) ratio which was significant (P = 0.007). The 2.5%-97.5% limits of asymmetry were 9 μm for average RNFL, 0.14 for average CD ratio, and 0.22 for vertical CD ratio. Mean interocular RNFL thickness differences in superior, superior nasal, and temporal superior quadrants were 10.61 (P < 0.001), 12.57 (P < 0.001), and 4.46 (P = 0.002) μm, respectively. Interocular nerve fiber layer thickness differences were not significantly correlated with sex, while only significant differences with age were observed in 12 clock hour sector analysis, mainly in nasal inferior and inferior quadrant.
We report the degree of interocular symmetry of RNFL and ONH parameters measured by Cirrus HD-OCT in a healthy pediatric population. The normal interocular RNFL asymmetry should not exceed 9 μm and vertical CD ratio beyond 0.22 should be considered for further investigations. The physiologic asymmetry provided by this study may assist in identifying changes in RNFL thickness and ONH parameters in pediatric glaucoma and ONH disorders.
使用Cirrus高清光学相干断层扫描(HD - OCT)确定儿科人群视网膜神经纤维层(RNFL)和视神经乳头(ONH)参数的眼间差异。
本观察性横断面研究纳入了70名到儿科门诊就诊的5 - 17岁正常印度儿童。所有受试者均接受了全面的眼科检查,并通过Cirrus HD - OCT对视神经纤维层和视神经乳头进行评估。计算右眼和左眼之间的差异,并通过配对t检验比较数值。受试者还根据年龄分为两组(10岁以下或10岁以上)。确定了RNFL和ONH参数的眼间差异以及这些差异的性别和年龄变化。
所研究儿科人群的平均年龄为11.83±3.3岁(范围5 - 17岁)。平均RNFL厚度为94.46±8.7μm(±标准差)(范围77 - 111)。右眼和左眼之间平均RNFL的差异无统计学意义(P = 0.060)。左眼的上象限RNFL较厚,右眼的颞象限RNFL较厚。在ONH参数中,除垂直杯盘(CD)比有显著差异(P = 0.007)外,其他参数均无统计学意义。平均RNFL的不对称性2.5% - 97.5%界限为9μm,平均CD比为0.14,垂直CD比为0.22。上、鼻上和颞上象限的平均眼间RNFL厚度差异分别为10.61(P < 0.001)、12.57(P < 0.001)和4.46(P = 0.002)μm。眼间神经纤维层厚度差异与性别无显著相关性,而在12个钟点扇形分析中仅观察到与年龄有显著差异,主要在鼻下象限和下象限。
我们报告了在健康儿科人群中通过Cirrus HD - OCT测量的RNFL和ONH参数的眼间对称程度。正常的眼间RNFL不对称不应超过9μm,垂直CD比超过0.22应考虑进一步检查。本研究提供的生理不对称性可能有助于识别儿科青光眼和ONH疾病中RNFL厚度和ONH参数的变化。