Suppr超能文献

瞬时心脏压力反射敏感性(xBRS)的有效性和变异性

Validity and variability of xBRS: instantaneous cardiac baroreflex sensitivity.

作者信息

Wesseling Karel H, Karemaker John M, Castiglioni Paolo, Toader Emil, Cividjian Andrei, Settels Jos J, Quintin Luc, Westerhof Berend E

机构信息

BMEye, Amsterdam, The Netherlands.

Department of Medical Biology (Section Systems Physiology), Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands

出版信息

Physiol Rep. 2017 Nov;5(22). doi: 10.14814/phy2.13509.

Abstract

Spontaneous oscillations of blood pressure (BP) and interbeat interval (IBI) may reveal important information on the underlying baroreflex control and regulation of BP We evaluated the method of continuously measured instantaneous baroreflex sensitivity by cross correlation (xBRS) validating its mean value against the gold standard of phenylephrine (Phe) and nitroprusside (SNP) bolus injections, and focusing on its spontaneous changes quantified as variability around the mean. For this purpose, we analyzed data from an earlier study of eight healthy males (aged 25-46 years) who had received Phe and SNP in conditions of baseline and autonomic blocking agents: atropine, propranolol, and clonidine. Average xBRS corresponds well to Phe/SNP-BRS, with xBRS levels ranging from 1.2 (atropine) to 102 msec/mmHg (subject asleep under clonidine). Time shifts from BP- to IBI-signal increased from ≤1 sec (maximum correlations within the current heartbeat) to 3-5 sec (under atropine). Plotted on a logarithmic vertical scale, xBRS values show 40% variability (defined as SD/mean) over the whole range in the various conditions, except twice when the subjects had fallen asleep and it dropped to 20%. The xBRS oscillates at frequencies of 0.1 Hz and lower, dominant between 0.02-0.05 Hz. Although xBRS is the result of IBI/BP-changes, no linear coherence was found in the cross-spectra of the xBRS-signal and IBI or BP We speculate that the level of variability in the xBRS-signal may act as a probe into the central nervous condition, as evidenced in the two subjects who fell asleep with high xBRS and only 20% of relative variation.

摘要

血压(BP)和心动周期(IBI)的自发振荡可能揭示有关潜在压力反射控制和血压调节的重要信息。我们评估了通过互相关(xBRS)连续测量瞬时压力反射敏感性的方法,将其平均值与去氧肾上腺素(Phe)和硝普钠(SNP)推注的金标准进行验证,并关注其作为均值周围变异性量化的自发变化。为此,我们分析了一项早期研究的数据,该研究涉及8名健康男性(年龄25 - 46岁),他们在基线和自主神经阻滞剂(阿托品、普萘洛尔和可乐定)条件下接受了Phe和SNP。平均xBRS与Phe/SNP - BRS对应良好,xBRS水平范围从1.2(阿托品)至102毫秒/毫米汞柱(受试者在可乐定作用下入睡)。从血压信号到IBI信号的时间偏移从≤1秒(当前心跳内的最大相关性)增加到3 - 5秒(阿托品作用下)。以对数垂直标度绘制时,xBRS值在各种条件下的整个范围内显示出40%的变异性(定义为标准差/均值),除了受试者入睡两次时变异性降至20%。xBRS在0.1赫兹及更低频率振荡,在0.02 - 0.05赫兹之间占主导。尽管xBRS是IBI/BP变化的结果,但在xBRS信号与IBI或BP的互谱中未发现线性相干性。我们推测xBRS信号中的变异性水平可能作为中枢神经状态的一个指标,这在两名xBRS高且相对变化仅20%的入睡受试者中得到了证明。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/91ad/5704083/213ebc3d338d/PHY2-5-e13509-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验