J Cataract Refract Surg. 2017 Nov;43(11):1420-1429. doi: 10.1016/j.jcrs.2017.08.013.
To evaluate the influences of preoperative pupil parameters on the visual outcomes of the SBL-3, a rotationally asymmetric multifocal intraocular lens (IOL) with a surface-embedded near segment.
Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom.
Retrospective comparative case series.
Postoperatively, patients divided into 4 groups according to their pupil size as follows: Group A: 2.50 to 2.99 mm, Group B: 3.00 to 3.50 mm, Group C: 3.51 to 4.00 mm, and Group D: 4.01 to 4.50 mm. The uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities, IOL centration and tilt, and quality of vision (QoV) questionnaires were compared between the 4 groups for 18 months postoperatively.
The study comprised 90 patients (180 eyes). The mean preoperative pupil (photopic and mesopic) diameter was 4.3 mm ± 0.3 (SD) and 5.6 ± 1.4 mm, respectively, which decreased to 3.8 ± 0.7 mm and 4.9 ± 1.2 mm, respectively, at 18 months. Eighteen months postoperatively, both photopic and mesopic pupil groups had a statistically significant reduction in size from preoperative levels. No significant differences in UDVA, UIVA, and UNVA were found between the groups (P > .001). Significant differences in the QoV questionnaire day scores and night scores were found between the 4 groups (P < .001).
The rotationally asymmetric multifocal IOL provided excellent optical performance during 18-months follow-up. The preoperative photopic pupil is an important parameter for consideration of this type of IOL because smaller pupils have a significant negative subjective impact on QoV.
评估术前瞳孔参数对 SBL-3 的视觉效果的影响,SBL-3 是一种具有表面嵌入式近节段的旋转不对称多焦点人工晶状体(IOL)。
英国北爱尔兰贝尔法斯特大教堂眼科诊所。
回顾性比较病例系列。
术后根据瞳孔大小将患者分为 4 组:A 组:2.50 至 2.99mm;B 组:3.00 至 3.50mm;C 组:3.51 至 4.00mm;D 组:4.01 至 4.50mm。术后 18 个月比较 4 组的未矫正距离(UDVA)、中间距离(UIVA)和近距(UNVA)视力、IOL 中心和倾斜度以及视觉质量(QoV)问卷。
本研究共纳入 90 例(180 只眼)患者。平均术前瞳孔(明视和中间)直径分别为 4.3±0.3(SD)和 5.6±1.4mm,术后 18 个月分别降至 3.8±0.7mm 和 4.9±1.2mm。术后 18 个月,明视和中间瞳孔组的瞳孔均较术前显著缩小。各组间 UDVA、UIVA 和 UNVA 差异均无统计学意义(P>.001)。4 组 QoV 问卷日间和夜间评分差异均有统计学意义(P<.001)。
旋转不对称多焦点 IOL 在 18 个月的随访中提供了出色的光学性能。术前明视瞳孔是考虑这种 IOL 的重要参数,因为较小的瞳孔对 QoV 有显著的负面影响。