Suppr超能文献

Spotiton:新特性和新应用。

Spotiton: New features and applications.

机构信息

The National Resource for Automated Molecular Microscopy, Simons Electron Microscopy Center, New York Structural Biology Center, 89 Convent Ave, New York, NY, USA.

The National Resource for Automated Molecular Microscopy, Simons Electron Microscopy Center, New York Structural Biology Center, 89 Convent Ave, New York, NY, USA; Department of Biochemistry and Molecular Biophysics, Columbia University, New York, NY, USA.

出版信息

J Struct Biol. 2018 May;202(2):161-169. doi: 10.1016/j.jsb.2018.01.002.

Abstract

We present an update describing new features and applications of Spotiton, a novel instrument for vitrifying samples for cryoEM. We have used Spotiton to prepare several test specimens that can be reconstructed using routine single particle analysis to ∼3 Å resolution, indicating that the process has no apparent deleterious effect on the sample integrity. The system is now in routine and continuous use in our lab and has been used to successfully vitrify a wide variety of samples.

摘要

我们介绍了一种新型的用于冷冻电镜样品玻璃化的仪器 Spotiton 的更新版本,描述了其新特性和新应用。我们使用 Spotiton 制备了几个测试样本,这些样本可以使用常规的单颗粒分析方法重建到约 3Å 的分辨率,这表明该过程对样品完整性没有明显的有害影响。该系统现在在我们的实验室中常规且持续使用,并已成功用于各种样品的玻璃化。

相似文献

1
Spotiton: New features and applications.
J Struct Biol. 2018 May;202(2):161-169. doi: 10.1016/j.jsb.2018.01.002.
2
Optimizing "self-wicking" nanowire grids.
J Struct Biol. 2018 May;202(2):170-174. doi: 10.1016/j.jsb.2018.01.001. Epub 2018 Jan 6.
3
Spotiton: a prototype for an integrated inkjet dispense and vitrification system for cryo-TEM.
J Struct Biol. 2012 Jul;179(1):68-75. doi: 10.1016/j.jsb.2012.04.020. Epub 2012 May 5.
4
A new method for vitrifying samples for cryoEM.
J Struct Biol. 2016 Aug;195(2):190-198. doi: 10.1016/j.jsb.2016.06.001. Epub 2016 Jun 8.
5
Time-resolved cryo-EM using Spotiton.
Nat Methods. 2020 Sep;17(9):897-900. doi: 10.1038/s41592-020-0925-6. Epub 2020 Aug 10.
6
7
Through-grid wicking enables high-speed cryoEM specimen preparation.
Acta Crystallogr D Struct Biol. 2020 Nov 1;76(Pt 11):1092-1103. doi: 10.1107/S2059798320012474. Epub 2020 Oct 13.
10
Strategies for Automated CryoEM Data Collection Using Direct Detectors.
Methods Enzymol. 2016;579:87-102. doi: 10.1016/bs.mie.2016.04.008. Epub 2016 Jun 22.

引用本文的文献

3
DNA Nanotags for Multiplexed Single-Particle Electron Microscopy and Electron Cryotomography.
JACS Au. 2024 Dec 27;5(1):17-27. doi: 10.1021/jacsau.4c00986. eCollection 2025 Jan 27.
4
RNA sample optimization for cryo-EM analysis.
Nat Protoc. 2025 May;20(5):1114-1157. doi: 10.1038/s41596-024-01072-1. Epub 2024 Nov 15.
5
Capturing a methanogenic carbon monoxide dehydrogenase/acetyl-CoA synthase complex via cryogenic electron microscopy.
Proc Natl Acad Sci U S A. 2024 Oct 8;121(41):e2410995121. doi: 10.1073/pnas.2410995121. Epub 2024 Oct 3.
6
Cryo-electron microscopy in the study of virus entry and infection.
Front Mol Biosci. 2024 Jul 24;11:1429180. doi: 10.3389/fmolb.2024.1429180. eCollection 2024.
8
Tuning ice thickness using the chameleon for high-quality cryoEM data collection.
bioRxiv. 2024 May 4:2024.05.01.592094. doi: 10.1101/2024.05.01.592094.
9
Applying 3D ED/MicroED workflows toward the next frontiers.
Acta Crystallogr C Struct Chem. 2024 Jun 1;80(Pt 6):179-189. doi: 10.1107/S2053229624004078. Epub 2024 May 7.
10
VitroJet: new features and case studies.
Acta Crystallogr D Struct Biol. 2024 Apr 1;80(Pt 4):232-246. doi: 10.1107/S2059798324001852. Epub 2024 Mar 15.

本文引用的文献

1
Opinion: hazards faced by macromolecules when confined to thin aqueous films.
Biophys Rep. 2017;3(1):1-7. doi: 10.1007/s41048-016-0026-3. Epub 2016 Jul 22.
2
Addressing preferred specimen orientation in single-particle cryo-EM through tilting.
Nat Methods. 2017 Aug;14(8):793-796. doi: 10.1038/nmeth.4347. Epub 2017 Jul 3.
3
A Fast and Effective Microfluidic Spraying-Plunging Method for High-Resolution Single-Particle Cryo-EM.
Structure. 2017 Apr 4;25(4):663-670.e3. doi: 10.1016/j.str.2017.02.005. Epub 2017 Mar 9.
4
MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy.
Nat Methods. 2017 Apr;14(4):331-332. doi: 10.1038/nmeth.4193. Epub 2017 Feb 27.
5
Blotting-free and lossless cryo-electron microscopy grid preparation from nanoliter-sized protein samples and single-cell extracts.
J Struct Biol. 2017 Mar;197(3):220-226. doi: 10.1016/j.jsb.2016.11.002. Epub 2016 Nov 15.
6
A new method for vitrifying samples for cryoEM.
J Struct Biol. 2016 Aug;195(2):190-198. doi: 10.1016/j.jsb.2016.06.001. Epub 2016 Jun 8.
7
CTFFIND4: Fast and accurate defocus estimation from electron micrographs.
J Struct Biol. 2015 Nov;192(2):216-21. doi: 10.1016/j.jsb.2015.08.008. Epub 2015 Aug 13.
8
Crystal structure, conformational fixation and entry-related interactions of mature ligand-free HIV-1 Env.
Nat Struct Mol Biol. 2015 Jul;22(7):522-31. doi: 10.1038/nsmb.3051. Epub 2015 Jun 22.
9
Spotiton: a prototype for an integrated inkjet dispense and vitrification system for cryo-TEM.
J Struct Biol. 2012 Jul;179(1):68-75. doi: 10.1016/j.jsb.2012.04.020. Epub 2012 May 5.
10
Shear free and blotless cryo-TEM imaging: a new method for probing early evolution of nanostructures.
Langmuir. 2012 Mar 6;28(9):4043-6. doi: 10.1021/la204992y. Epub 2012 Feb 22.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验