A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum α-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA). A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents, less total assay time, and better linearity, recovery, precision, sensitivity and validity. AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA, and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit. The correlation coefficient between MPs-CLEIA and ELISA was obtained with =0.6703; however, the correlation between MPs-CLEIA and ECLIA (=0.9582) was obviously better than that between colorimetric ELISA and ECLIA (=0.6866).
开发了一种基于磁性微粒的化学发光酶免疫分析方法(MmPs-CLEIA),用于与传统比色酶联免疫吸附测定法(ELISA)并行评估血清甲胎蛋白(AFP)。MmPs-CLEIA与比色ELISA之间的系统比较得出结论,磁性微粒化学发光酶免疫分析方法使用的免疫试剂剂量更少,总检测时间更短,并且线性、回收率、精密度、灵敏度和有效性更好。通过所提出的磁性微粒化学发光酶免疫分析方法和ELISA对40份人血清样本中的AFP进行了检测,并将结果与商业电化学发光免疫分析(ECLIA)试剂盒进行了比较。磁性微粒化学发光酶免疫分析方法与ELISA之间的相关系数为r = 0.6703;然而,磁性微粒化学发光酶免疫分析方法与ECLIA之间的相关性(r = 0.9582)明显优于比色ELISA与ECLIA之间的相关性(r = 0.6866)。