Suppr超能文献

使用商用手持仪器测量无创破裂时间、脂质形态和泪液半月板高度的文献综述。

Review of Literature on Measurements of Non-invasive Break Up Times, Lipid Morphology and Tear Meniscal Height Using Commercially Available Hand-held Instruments.

作者信息

Tong Louis, Teng Lim Shee

机构信息

a Singapore National Eye Centre , Singapore.

b Singapore Eye Research Institute , Singapore.

出版信息

Curr Eye Res. 2018 May;43(5):567-575. doi: 10.1080/02713683.2018.1437454. Epub 2018 Feb 16.

Abstract

UNLABELLED

Purpose/aims: Dry eye is a common multi-factorial disease characterized by tearfilm dysfunction. Diagnosis of dry eye requires documentation of tear status with non-invasive tear break up times (NIBUT), tear meniscal height (TMH), and tearfilm lipid layer. These parameters objectively assess tear stability and indirectly, the functional impact of meibomian gland dysfunction. While it is obvious that portable instrumentation gives broader access than fixed instrumentation, its value would be limited if it is unreliable and its precision and accuracy substantially worse than fixed instruments.

MATERIALS/METHODS: Because of the lack of systematic reviews concerning the Tearscope, we performed a scoping review of the literature to determine 1. the ranges of the tear parameters as measured by the device, 2. relationship between these measurements and other clinical variables, 3. Information about intra or inter-observer agreement, and comparison with another technique, where available.

RESULTS

We found 22 reports related to NIBUT, 18 reports concerning tearfilm lipid morphology (LM) based on classification of interference patterns, and 8 reports on TMH. While publication of these reports indicates an acceptance of the reliability of portable instruments, we interrogated these studies further to evaluate the results obtained from portable devices and found that there was no equivalent measurements in fixed devices (LM) or measurements differ considerably from fixed devices (NIBUT). In the case of TMH, portable measurements were similar to those by traditional slit-lamp microscopy. There were relatively few studies on TMH measured using handheld devices, but it was found to be correlated to NIBUT but not the Schirmer test values.

CONCLUSIONS

Imaging algorithms in portable tearfilm instruments should be further standardized to facilitate wider adoption and evaluation. In the next few years, new emerging technologies will employ a strategy of non-invasive tear testing that is portable and relatively inexpensive, and these will enhance adoption of such tools in the clinic.

摘要

未标记

目的/目标:干眼症是一种常见的多因素疾病,其特征为泪膜功能障碍。干眼症的诊断需要通过非侵入性泪膜破裂时间(NIBUT)、泪河高度(TMH)和泪膜脂质层来记录泪液状态。这些参数可客观评估泪液稳定性,并间接评估睑板腺功能障碍的功能影响。虽然便携式仪器显然比固定式仪器更易于使用,但其价值将受到限制,如果它不可靠且其精度和准确性明显低于固定式仪器。

材料/方法:由于缺乏关于泪膜镜的系统评价,我们对文献进行了范围综述,以确定1. 该设备测量的泪液参数范围,2. 这些测量值与其他临床变量之间的关系,3. 观察者内或观察者间一致性的信息,以及与其他可用技术相比的情况。

结果

我们发现22篇与NIBUT相关的报告,18篇关于基于干涉图案分类的泪膜脂质形态(LM)的报告,以及8篇关于TMH的报告。虽然这些报告的发表表明便携式仪器的可靠性已被接受,但我们进一步审视这些研究,以评估从便携式设备获得的结果,发现固定设备中没有等效测量值(LM),或者测量值与固定设备有很大差异(NIBUT)。在TMH方面,便携式测量与传统裂隙灯显微镜测量相似。使用手持设备测量TMH的研究相对较少,但发现它与NIBUT相关,而与泪液分泌试验值无关。

结论

便携式泪膜仪器中的成像算法应进一步标准化,以促进更广泛的应用和评估。在未来几年,新兴技术将采用便携式且相对便宜的非侵入性泪液检测策略,这将提高此类工具在临床中的应用。