Suppr超能文献

韩国住宅环境中的氡浓度。

Indoor radon concentration in Korea residential environments.

机构信息

Department of Chemical and Biological Engineering, SeoKyeong University, Seoul, 02713, South Korea.

Institute of Genomic Cohort, College of Medicine, Yonsei University, Wonju, 26493, South Korea.

出版信息

Environ Sci Pollut Res Int. 2018 May;25(13):12678-12685. doi: 10.1007/s11356-018-1531-3. Epub 2018 Feb 21.

Abstract

The purpose of this study is to provide basic data for the evaluation and management of health effects with respect to exposure to radon within residential environments in South Korea. It is part of a case-control study to develop a management plan based on indoor radon exposure levels and assess their impact on health. To investigate the long-term cumulative concentration levels of radon, 599 patients who have respiratory diseases were recruited in South Korea, and alpha track detectors were installed in their residences for a period of 3 months from mid-2015 to late 2016. A survey was then conducted to determine the factors affecting the radon concentration. The radon concentration levels were analyzed in conjunction with the survey results. The results show that the arithmetic mean of the radon concentrations in domestic residences was in the range of 70.8 ± 65.2 Bq/m. An analysis of covariance (ANCOVA) was performed to identify the environmental factors affecting the radon concentration and contributing to variations in the residential radon concentration based on the height of the residence. The results show that the contribution of the local environmental factor to the variation in radon concentration (p < 0.05) was greater than that of other environmental factors. Although no statistically significant difference was found with regard to the construction year of the building before the control (p > 0.05), the same was found with regard to the construction year after the control (p < 0.05).

摘要

本研究旨在为评估和管理韩国住宅环境中氡暴露对健康的影响提供基础数据。它是一项基于室内氡暴露水平制定管理计划并评估其对健康影响的病例对照研究的一部分。为了研究氡的长期累积浓度水平,2015 年中期至 2016 年末,在韩国招募了 599 名患有呼吸道疾病的患者,并在他们的住所中安装了α径迹探测器,为期 3 个月。然后进行了一项调查,以确定影响氡浓度的因素。结合调查结果对氡浓度水平进行了分析。结果表明,国内住宅中氡浓度的算术平均值在 70.8 ± 65.2 Bq/m 范围内。为了根据住宅高度确定影响氡浓度的环境因素并确定住宅氡浓度的变化,进行了协方差分析(ANCOVA)。结果表明,局部环境因素对氡浓度变化的贡献(p < 0.05)大于其他环境因素。尽管在控制前建筑物的建造年份方面没有发现统计学上的显著差异(p > 0.05),但在控制后建筑物的建造年份方面发现了相同的情况(p < 0.05)。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验