Suppr超能文献

使用GlideTrak™进行体重支持下跑步机跑步时的心率和VO反应。

Heart rate and VO responses to treadmill running with body weight support using the GlideTrak™.

作者信息

Perry Jordan, Johnson Wayne, Fellingham Gilbert W, Vehrs Pat R

机构信息

Department of Exercise Sciences, Brigham Young University, Provo, UT, 84602, USA.

Department of Statistics, Brigham Young University, Provo, UT, 84602, USA.

出版信息

J Exerc Sci Fit. 2017 Jun;15(1):32-36. doi: 10.1016/j.jesf.2017.06.002. Epub 2017 Jun 29.

Abstract

BACKGROUND/OBJECTIVE: The heart rate (HR) and metabolic (VO) responses to treadmill running using the GlideTrak™ body weight support system have not been reported. The purpose of this study was to compare the submaximal and maximal HR and VO responses to normal-weight treadmill running (TMR) to treadmill running with body weight support provided by the GlideTrak™ (GTR).

METHODS

Twenty participants (11 males; 9 females) 18 to 26 years of age voluntarily participated in this study. Each participant completed two exercise tests in each mode of running: a maximal graded exercise test to compare maximal HR and VO values and a submaximal exercise test to compare the HR-VO relationship.

RESULTS

Maximal HR and VO values were significantly ( < 0.001) lower during GTR (183.4 ± 9.1 bpm, 38.1 ± 7.2 mL kg min) compared to TMR (194.3 ± 8.6 bpm, 49.5 ± 8.9 kg min). There was a significant difference in the HR-VO relationship between GTR and TMR. Compared to TMR, exercising at a HR of 140 bpm resulted in a VO that was 4.0 mL kg min lower during GTR. At the VO associated with a HR of 140 bpm during TMR, the HR during GTR was 16 bpm higher. During GTR at intensities of exercise up to an RER of 1.0, only 8 participants achieved vigorous intensities of aerobic exercise defined as 64-90% of VOmax.

CONCLUSION

Exercising with the GlideTrak™ body weight support system may not provide the same cardiorespiratory training stimulus as normal-weight treadmill running.

摘要

背景/目的:使用GlideTrak™体重支持系统进行跑步机跑步时的心率(HR)和代谢(VO)反应尚未见报道。本研究的目的是比较正常体重跑步机跑步(TMR)与使用GlideTrak™(GTR)提供体重支持的跑步机跑步时的次最大和最大HR及VO反应。

方法

20名年龄在18至26岁之间的参与者(11名男性;9名女性)自愿参加本研究。每位参与者在每种跑步模式下完成两项运动测试:一项最大分级运动测试以比较最大HR和VO值,以及一项次最大运动测试以比较HR-VO关系。

结果

与TMR(194.3±8.6次/分钟,49.5±8.9毫升·千克·分钟)相比,GTR期间的最大HR和VO值显著更低(<0.001)(183.4±9.1次/分钟,38.1±7.2毫升·千克·分钟)。GTR和TMR之间的HR-VO关系存在显著差异。与TMR相比,在GTR期间心率为140次/分钟时进行运动,VO值低4.0毫升·千克·分钟。在TMR期间心率为140次/分钟时的VO值对应的运动强度下,GTR期间的心率高16次/分钟。在GTR期间,运动强度达到呼吸交换率(RER)为1.0时,只有8名参与者达到了定义为最大摄氧量(VOmax)的64%-90%的有氧运动高强度。

结论

使用GlideTrak™体重支持系统进行运动可能无法提供与正常体重跑步机跑步相同的心肺训练刺激。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fa3f/5812853/5be15dc5d3ba/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验