Suppr超能文献

高强度聚焦超声在印度患者开角型青光眼治疗中的应用。

Application of high intensity focused ultrasound for treatment of open-angle glaucoma in Indian patients.

机构信息

Department of Glaucoma, Winvision Eye Hospital, Hyderabad, Telangana, India.

Department of Glaucoma, Maxivision Eye Hospital, Hyderabad, Telangana, India.

出版信息

Indian J Ophthalmol. 2018 Apr;66(4):517-523. doi: 10.4103/ijo.IJO_1024_17.

Abstract

PURPOSE

The aim of this study is to assess the efficacy of ultrasound cycloplasty (UCP) in Indian patients with open angle glaucoma (OAG).

METHODS

A prospective interventional study was designed to treat 73 eyes of 73 patients with OAG with the EyeOP1 device equipped with six miniaturized cylindrical piezoelectric transducers. Two treatment protocols of ultrasound delivery depending on exposure time (8 s and 10 s of shot per transducer) were used. Complete ophthalmic examination, ocular biometry and anterior segment optical coherence tomography were performed preoperatively and patients were followed up at day 1, day 7 and months 1, 2, 3, 6, and 12. The primary outcome measure was "successful" intraocular pressure (IOP) control defined as IOP reduction ≥20% from baseline and IOP value >5 mm Hg at the last follow-up visit. Secondary outcomes were the occurrence of complications and mean IOP during the follow-up period.

RESULTS

In all patients, the mean IOP reduced from 23.5 ± 3.0 mmHg before treatment to 15.7 ± 5.4 mmHg at 12 months (P < 0.05). Successful IOP control after a single procedure was 78.3% (79% and 78% in the 8 s and 10 s groups, respectively) at 12 months. Overall, the mean IOP reduction achieved in responding patients was 41% (standard deviation = 12%). Notwithstanding minor side effects such as transient pain, anterior chamber reaction, and refractive error changes, no major intraoperative or postoperative complications (severe hypotony or phthisis) were observed during the follow-up.

CONCLUSION

Our short-term results reveal that UCP is a simple, safe, and noninvasive procedure which enables to significantly reduce the IOP in patients with OAG. The study results in Indian eyes corroborate findings in earlier studies on Caucasian eyes.

摘要

目的

本研究旨在评估超声睫状体成形术(UCP)在印度开角型青光眼(OAG)患者中的疗效。

方法

设计了一项前瞻性干预研究,使用配备六个微型圆柱形压电换能器的 EyeOP1 设备治疗 73 例 73 只 OAG 眼。采用两种基于曝光时间的超声输送治疗方案(每个换能器 8 秒和 10 秒的射流)。术前进行全面眼科检查、眼生物测量和眼前节光学相干断层扫描,并在第 1 天、第 7 天以及第 1、2、3、6 和 12 个月进行随访。主要观察指标为“成功”的眼压(IOP)控制,定义为从基线下降≥20%且最后一次随访时 IOP 值>5mmHg。次要观察指标为并发症的发生和随访期间的平均 IOP。

结果

所有患者的平均 IOP 从治疗前的 23.5±3.0mmHg 降至 12 个月时的 15.7±5.4mmHg(P<0.05)。单次治疗后 12 个月时的 IOP 控制成功率为 78.3%(8s 和 10s 组分别为 79%和 78%)。总的来说,反应良好的患者平均 IOP 降低了 41%(标准差=12%)。尽管有轻微的副作用,如短暂疼痛、前房反应和屈光不正变化,但在随访期间未观察到严重的术中或术后并发症(严重低眼压或眼球萎缩)。

结论

我们的短期结果表明,UCP 是一种简单、安全、非侵入性的治疗方法,可显著降低 OAG 患者的 IOP。该研究结果在印度人群中与以前在白种人群中的研究结果一致。