Fishbein Kenneth W, Makrogiannis Sokratis K, Lukas Vanessa A, Okine Marilyn, Ramachandran Ramona, Ferrucci Luigi, Egan Josephine M, Chia Chee W, Spencer Richard G
Intramural Research Program, National Institute on Aging, National Institutes of Health, 251 Bayview Blvd., Baltimore, MD 21224, USA.
Intramural Research Program, National Institute on Aging, National Institutes of Health, 251 Bayview Blvd., Baltimore, MD 21224, USA.
Magn Reson Imaging. 2018 Jul;50:110-118. doi: 10.1016/j.mri.2018.03.016. Epub 2018 Mar 29.
To develop a protocol to non-invasively measure and map fat fraction, fat/(fat+water), as a function of age in the adult thymus for future studies monitoring the effects of interventions aimed at promoting thymic rejuvenation and preservation of immunity in older adults.
Three-dimensional spoiled gradient echo 3T MRI with 3-point Dixon fat-water separation was performed at full inspiration for thymus conspicuity in 36 volunteers 19 to 56 years old. Reproducible breath-holding was facilitated by real-time pressure recording external to the console. The MRI method was validated against localized spectroscopy in vivo, with ECG triggering to compensate for stretching during the cardiac cycle. Fat fractions were corrected for T and T bias using relaxation times measured using inversion recovery-prepared PRESS with incremented echo time.
In thymus at 3 T, T = 978 ± 75 ms, T = 323 ± 37 ms, T = 43.4 ± 9.7 ms and T = 52.1 ± 7.6 ms were measured. Mean T-corrected MRI fat fractions varied from 0.2 to 0.8 and were positively correlated with age, weight and body mass index (BMI). In subjects with matching MRI and MRS fat fraction measurements, the difference between these measurements exhibited a mean of -0.008 with a 95% confidence interval of (0.123, -0.138).
3-point Dixon MRI of the thymus with T bias correction produces quantitative fat fraction maps that correlate with T-corrected MRS measurements and show age trends consistent with thymic involution.
制定一项方案,以无创方式测量和绘制成年胸腺中脂肪分数(脂肪/(脂肪 + 水))随年龄变化的情况,用于未来监测旨在促进老年人胸腺复壮和维持免疫力的干预措施效果的研究。
对36名年龄在19至56岁的志愿者进行了三维扰相梯度回波3T磁共振成像(MRI),采用三点 Dixon 脂肪 - 水分离技术,在完全吸气时进行成像以清晰显示胸腺。通过控制台外部的实时压力记录来辅助实现可重复的屏气。该MRI方法通过体内局部光谱学进行验证,并采用心电图触发来补偿心动周期中的拉伸。使用具有递增回波时间的反转恢复准备的 PRESS 序列测量的弛豫时间对脂肪分数进行T1和T2偏倚校正。
在3T磁场下的胸腺中,测量得到T1 = 978 ± 75 ms,T2 = 323 ± 37 ms,T2* = 43.4 ± 9.7 ms和T1ρ = 52.1 ± 7.6 ms。经T1校正后的平均MRI脂肪分数在0.2至0.8之间变化,且与年龄、体重和体重指数(BMI)呈正相关。在MRI和磁共振波谱(MRS)脂肪分数测量匹配的受试者中,这些测量之间的差异均值为 -0.008,95%置信区间为( -0.123, 0.138)。
经T1偏倚校正的胸腺三点 Dixon MRI可生成与经T1校正的MRS测量相关的定量脂肪分数图,并显示出与胸腺退化一致的年龄趋势。