Cornea. 2020 Jun;39(6):691-696. doi: 10.1097/ICO.0000000000002256.
To compare the degree of corneal light scatter as measured by densitometry in ultrathin Descemet Stripping Automated Endothelial Keratoplasty (UT-DSAEK) and Descemet Membrane Endothelial Keratoplasty (DMEK) in the Descemet endothelial thickness comparison trial.
This was a prespecified secondary analysis of the Descemet endothelial thickness comparison trial, which was a prospective, randomized controlled trial. Subjects with isolated endothelial dysfunction were enrolled and were randomized to either UT-DSAEK or DMEK. Corneal opacity was quantitatively measured by Pentacam densitometry (OCULUS) at 3, 6, and 12 months.
Fifty eyes of 38 patients were enrolled at the Casey Eye Institute at Oregon Health & Science University and the Byers Eye Institute at Stanford University. Corneal densitometry for the anterior and posterior layers improved in both UT-DSAEK and DMEK after surgery. The decrease was more pronounced in the posterior layer for both groups. However, there was no difference in the degree of corneal light scatter between UT-DSAEK and DMEK at postoperative month 12, and no difference in change in densitometry was observed between the 2 arms from baseline to month 12.
Both UT-DSAEK and DMEK experience an improvement in the degree of corneal light scatter after surgery. However, there was no difference in densitometry between the 2 groups at month 12. Therefore, other factors such as higher order aberrations in the posterior cornea rather than stromal-stromal interface haze mediate the superior visual outcomes in DMEK compared with UT-DSAEK.
通过密度测定法比较超薄 Descemet 撕囊自动角膜内皮移植术(UT-DSAEK)和 Descemet 膜内皮角膜移植术(DMEK)中角膜光散射程度,该研究为 Descemet 内皮厚度比较试验的预设二次分析。
这是一项前瞻性、随机对照试验——Descemet 内皮厚度比较试验的预设二次分析。入选孤立性内皮功能障碍的患者,并将其随机分为 UT-DSAEK 组或 DMEK 组。术后 3、6 和 12 个月,采用 Pentacam 密度仪(OCULUS)定量测量角膜混浊度。
在俄勒冈健康与科学大学 Casey 眼科研究所和斯坦福大学 Byers 眼科研究所共纳入 38 例 50 只眼。术后,UT-DSAEK 和 DMEK 组的前、后角膜层密度均有改善,两组的后层下降更明显。然而,术后 12 个月时,UT-DSAEK 和 DMEK 之间角膜光散射程度无差异,从基线到术后 12 个月,2 组间密度测量值的变化也无差异。
UT-DSAEK 和 DMEK 术后角膜光散射程度均有改善,但术后 12 个月时 2 组间密度测量值无差异。因此,与 UT-DSAEK 相比,DMEK 术后具有更好的视觉效果,可能与后角膜高阶像差而非基质-基质界面混浊等其他因素有关。