斑贴试验部位皮肤血流的定量分析。

Quantification of skin blood flow at patch test sites.

作者信息

Wahlberg J E, Wahlberg E N

机构信息

Department of Occupational Dermatology, Karolinska Hospital, Stockholm, Sweden.

出版信息

Contact Dermatitis. 1987 Oct;17(4):229-33. doi: 10.1111/j.1600-0536.1987.tb02718.x.

Abstract

Irritancy caused by the patch test procedure itself can be evaluated by measuring the skin blood flow with a laser Doppler flowmeter before application of the patches and at intervals after their removal. To investigate this technique further, van der Bend and True test patches with and without nickel sulfate were applied to the skin of the back and to the volar forearm in healthy subjects. Immediately after removal of the patches, the blood flow values in 26 of 32 test sites were higher than the corresponding pre-application values. In the majority of cases, blood flow had returned to pre-application values at 72 h (24 h after removal). This favours these patches compared to those used in previous studies (A1-test, Finn chambers, Silver patches), which caused a more lasting effect on skin blood flow. The common practice of relying mainly on the 72 h and 96 h readings of patch test sites was thus justified.

摘要

通过在贴敷贴片之前以及移除贴片后的不同时间间隔,使用激光多普勒血流仪测量皮肤血流,可以评估贴片试验程序本身所引起的刺激性。为了进一步研究该技术,在健康受试者的背部皮肤和掌侧前臂上分别贴敷含有和不含硫酸镍的试验贴片。移除贴片后,立即发现32个试验部位中的26个部位的血流值高于相应的贴敷前值。在大多数情况下,72小时(移除后24小时)时血流已恢复到贴敷前的值。与先前研究中使用的贴片(A1试验、芬兰小室、银贴片)相比,这种贴片更具优势,因为先前研究中的贴片对皮肤血流产生了更持久的影响。因此,主要依赖于贴片试验部位72小时和96小时读数的常规做法是合理的。