Suppr超能文献

相同平台的双焦点和三焦点人工晶状体植入术后视觉性能比较

Comparison of the Visual Performance After Implantation of Bifocal and Trifocal Intraocular Lenses Having an Identical Platform.

作者信息

Liu Xiaomin, Xie Lixin, Huang Yusen

出版信息

J Refract Surg. 2018 Apr 1;34(4):273-280. doi: 10.3928/1081597X-20180214-01.

Abstract

PURPOSE

To compare the visual performance after bilateral implantation of a diffractive bifocal or trifocal intraocular lens (IOL) from the same manufacturer using the same IOL platform.

METHODS

This prospective, non-randomized, controlled study involved patients who had cataract surgery with bilateral implantation of bifocal or trifocal IOLs. The near, intermediate, and distance visual acuities, defocus curve, optical quality including modulation transfer functions and higher-order aberrations, National Eye Institute Visual Functioning Questionnaire-14, patient satisfaction, spectacle independence, and perception of visual disturbances were assessed in all patients.

RESULTS

Fifty eyes (25 patients) were implanted with a diffractive trifocal IOL (AT LISA tri 839MP; Carl Zeiss Meditec, Jena, Germany) and 60 eyes (30 patients) with a diffractive bifocal IOL (AT LISA 809M; Carl Zeiss Meditec). The follow-up was 3 months. No statistically significant difference was found in distance or near visual acuity between the two groups (P ≥ .05). Uncorrected, corrected, and distance-corrected intermediate visual acuities were significantly better in the trifocal IOL group (P < .01). In the binocular defocus curve, the visual acuity was also significantly better for defocus of -1.00 to -2.00 diopters in eyes with trifocal IOL implantation (P < .01). Similar halos and glare were present in the two groups. The levels of overall satisfaction were similarly high between groups.

CONCLUSIONS

Diffractive trifocal IOLs can provide significantly better intermediate vision and equivalent distance and near visual performance compared to bifocal IOLs and do not induce extra qualitative vision disturbances. [J Refract Surg. 2018;34(4):273-280.].

摘要

目的

比较使用同一制造商的相同人工晶状体(IOL)平台双侧植入衍射双焦点或三焦点人工晶状体后的视觉性能。

方法

这项前瞻性、非随机、对照研究纳入了接受白内障手术并双侧植入双焦点或三焦点人工晶状体的患者。评估了所有患者的近、中、远距离视力、散焦曲线、包括调制传递函数和高阶像差在内的光学质量、美国国立眼科研究所视觉功能问卷-14、患者满意度、眼镜独立性以及视觉干扰感知情况。

结果

50只眼(25例患者)植入了衍射三焦点人工晶状体(AT LISA tri 839MP;德国耶拿卡尔蔡司医疗技术公司),60只眼(3例患者)植入了衍射双焦点人工晶状体(AT LISA 809M;德国耶拿卡尔蔡司医疗技术公司)。随访时间为3个月。两组之间的远距离或近距离视力没有统计学上的显著差异(P≥0.05)。三焦点人工晶状体组的未矫正、矫正和远距离矫正后的中距离视力明显更好(P<0.01)。在双眼散焦曲线中,植入三焦点人工晶状体的眼睛在-1.00至-2.00屈光度散焦时的视力也明显更好(P<0.01)。两组中出现的光晕和眩光情况相似。两组之间总体满意度水平同样较高。

结论

与双焦点人工晶状体相比,衍射三焦点人工晶状体可提供明显更好的中距离视力以及等效的远距离和近距离视觉性能,且不会引发额外的视觉质量干扰。[《屈光手术杂志》。2018年;34(4):273-280。]

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验