Abstract

PURPOSE

To compare visual and contrast sensitivity (CS) outcomes, reading skills, and spectacle independence in patients implanted with two models of trifocal intraocular lenses (IOLs) or an extended range of vision (ERV) IOL.

METHODS

This non-randomized prospective series of cases included 120 eyes of 60 patients undergoing cataract surgery with bilateral implantation of three different IOLs: the ERV IOL Tecnis Symfony (40 eyes) (Abbott Medical Optics), the trifocal IOLs PanOptix IQ (40 eyes) (Alcon), and AT LISA tri 839MP (40 eyes) (Carl Zeiss Meditec). Visual results, photopic and mesopic CS, binocular reading skills (MNREAD charts), and patient satisfaction were evaluated 3 months after surgery.

RESULTS

There was no statistically significant difference between groups regarding uncorrected and corrected distance visual acuity. The Tecnis Symfony IOL showed better mesopic intermediate visual outcomes than the two trifocal IOLs (p < 0.05 vs AT LISA). Under photopic conditions, AT LISA tri 839MP and PanOptix IQ showed better near visual outcomes compared with the ERV IOL (p < 0.05 to p < 0.001). The Tecnis Symfony IOL provided significantly better photopic and mesopic CS outcomes than the other IOL models (p < 0.001). Reading skills were not significantly different between the three IOL models (p > 0.05). Less patients implanted with the two trifocal IOLs required a near addition than patients with the ERV IOL.

CONCLUSIONS

All the tested IOLs provided good visual outcome, reading performance, and spectacle independence after cataract surgery. While trifocal IOLs gave better near visual acuity results, the ERV IOL provided better contrast sensitivity.

摘要

目的

比较植入两种三焦点人工晶状体(IOL)或扩展视力范围(ERV)IOL的患者的视力和对比敏感度(CS)结果、阅读能力以及摆脱眼镜依赖的情况。

方法

本非随机前瞻性病例系列纳入了60例接受白内障手术并双侧植入三种不同IOL的患者的120只眼:ERV IOL Tecnis Symfony(40只眼)(雅培医疗光学公司)、三焦点IOL PanOptix IQ(40只眼)(爱尔康公司)和AT LISA tri 839MP(40只眼)(卡尔蔡司医疗技术公司)。术后3个月评估视力结果、明视和暗视CS、双眼阅读能力(MNREAD视力表)以及患者满意度。

结果

在未矫正和矫正远视力方面,各组之间无统计学显著差异。Tecnis Symfony IOL的暗视中间视力结果优于两种三焦点IOL(与AT LISA相比,p < 0.05)。在明视条件下,与ERV IOL相比,AT LISA tri 839MP和PanOptix IQ的近视力结果更好(p < 0.05至p < 0.001)。Tecnis Symfony IOL的明视和暗视CS结果明显优于其他IOL型号(p < 0.001)。三种IOL型号之间的阅读能力无显著差异(p > 0.05)。与植入ERV IOL的患者相比,植入两种三焦点IOL的患者中需要近附加镜的人数更少。

结论

所有测试的IOL在白内障手术后均能提供良好的视力结果、阅读表现和摆脱眼镜依赖的能力。虽然三焦点IOL的近视力结果更好,但ERV IOL的对比敏感度更高。