与法医尸检相比,死后计算机断层扫描中溺水病例胃内容物的分层情况。

Layering of stomach contents in drowning cases in post-mortem computed tomography compared to forensic autopsy.

作者信息

Gotsmy Walther, Lombardo Paolo, Jackowski Christian, Brencicova Eva, Zech Wolf-Dieter

机构信息

Institute of Forensic Medicine, University of Bern, Buehlstrasse 20, 3012, Bern, Switzerland.

Department of Diagnostic, Interventional and Pediatric Radiology, University of Bern, Inselspital, Freiburgstrasse 10, CH-3010, Bern, Switzerland.

出版信息

Int J Legal Med. 2019 Jan;133(1):181-188. doi: 10.1007/s00414-018-1850-4. Epub 2018 Apr 24.

Abstract

BACKGROUND

In forensic autopsy, the analysis of stomach contents is important when investigating drowning cases. Three-layering of stomach contents may be interpreted as a diagnostic hint to drowning due to swallowing of larger amounts of water or other drowning media. The authors experienced frequent discrepancies of numbers of stomach content layering in drowning cases between post-mortem computed tomography (PMCT) and autopsy in forensic casework. Therefore, the goal of this study was to compare layering of stomach contents in drowning cases between PMCT and forensic autopsy.

METHODS

Drowning cases (n = 55; 40 male, 15 female, mean age 45.3 years; mean amount of stomach content 223 ml) that received PMCT prior to forensic autopsy were retrospectively analyzed by a forensic pathologist and a radiologist. Number of layers of stomach content in PMCT were compared to number of layers at forensic autopsy.

RESULTS

In 28 of the 55 evaluated drowning cases, a discrepancy between layering of stomach contents at autopsy compared to PMCT was observed: 1 layer at autopsy (n = 28): 50% discrepancy to PMCT, 2 layers (n = 20): 45% discrepancy, and 3 layers (n = 7): 71.4% discrepancy. Sensitivity of correctly determining layering (as observed at forensic autopsy) in PMCT was 52% (positive predictive value 44.8%). Specificity was 46.6% (negative predictive value 53.8%). In a control group (n = 35) of non-drowning cases, three-layering of stomach contents was not observed.

CONCLUSION

Discrepancies of observed numbers of stomach content layers between PMCT and forensic autopsy are a frequent finding possibly due to stomach content sampling technique at autopsy and movement of the corpse prior to PMCT and autopsy. Three-layering in PMCT, if indeed present, may be interpreted as a hint to drowning.

摘要

背景

在法医尸检中,对胃内容物的分析在调查溺水案件时很重要。胃内容物的三层结构可能被解释为因大量吞咽水或其他溺水介质而导致溺水的诊断线索。作者在法医工作中经常遇到溺水案件中尸检计算机断层扫描(PMCT)和尸检时胃内容物分层数量的差异。因此,本研究的目的是比较PMCT和法医尸检中溺水案件胃内容物的分层情况。

方法

对在法医尸检前接受PMCT的溺水案件(n = 55;40名男性,15名女性,平均年龄45.3岁;胃内容物平均量223毫升)进行回顾性分析,由一名法医病理学家和一名放射科医生进行。将PMCT中胃内容物的层数与法医尸检时的层数进行比较。

结果

在55例评估的溺水案件中,有28例观察到尸检时胃内容物分层与PMCT存在差异:尸检时1层(n = 28):与PMCT的差异为50%,2层(n = 20):差异为45%,3层(n = 7):差异为71.4%。PMCT中正确确定分层(如法医尸检时观察到的)的敏感性为52%(阳性预测值44.8%)。特异性为46.6%(阴性预测值53.8%)。在非溺水案件的对照组(n = 35)中,未观察到胃内容物的三层结构。

结论

PMCT和法医尸检中观察到的胃内容物层数差异是常见现象,可能是由于尸检时胃内容物采样技术以及PMCT和尸检前尸体的移动所致。如果PMCT中确实存在三层结构,可解释为溺水的线索。