Patients with bilateral central field loss develop peripheral retinal loci (PRLs) in the functional eccentric retina. PRL characteristics and visual performance in the better-seeing eye (BE) of these patients have previously been reported. In this study, we determined the test-retest repeatability of fixation parameters, including fixation stability, PRL eccentricity, and PRL span in the worse-seeing eye (WE).
Retrospective consecutive case series.
Thirty-six patients with bilateral central field loss referred from the Toronto Western Hospital Retina Clinic, who had completed 2 consecutive fixation examinations on the same day.
Fixation stability was recorded using the Nidek MP-1 microperimeter (Nidek Technologies Srl., Padova, Italy). For each fixation recording, the following parameters were retrieved: (i) 68.2% bivariate contour ellipse area (BCEA), (ii) PRL span (major and minor axes of the BCEA), (iii) PRL meridian (polar angle), and (iv) PRL eccentricity. Test-retest repeatability for each parameter was assessed using Bland-Altman plots to determine 95% limits of agreement.
The mean difference between the fixation trial pairs and the 95% limits of agreement for fixation stability, PRL major axis, PRL minor axis, PRL meridian, and PRL eccentricity were 0.06 ± 0.47 log deg, 0.05° ± 1.42°, 0.07° ± 0.63°, -0.44° ± 66.0°, and -0.23° ±1.56°, respectively.
The fixation parameters in the WE showed robust repeatability, comparable to that of the BE as determined from previous studies. The WE's fixation repeatability should be considered in the interpretation of fixation outcome measures subsequent to treatment interventions.
双侧中央视野缺损患者在功能偏心视野中会发展出周边视网膜位置(PRL)。此前已有报道称,这些患者的较好眼(BE)的 PRL 特征和视力表现。在这项研究中,我们确定了在较差眼(WE)中,包括固视点稳定性、PRL 偏心度和 PRL 跨度在内的固视参数的测试-重测重复性。
回顾性连续病例系列。
36 名来自多伦多西部医院视网膜诊所的双侧中央视野缺损患者,他们在同一天完成了 2 次连续的固视检查。
使用 Nidek MP-1 微视野计(Nidek Technologies Srl.,帕多瓦,意大利)记录固视点稳定性。对于每个固视记录,我们获取以下参数:(i)68.2%双变量轮廓椭圆面积(BCEA),(ii)PRL 跨度(BCEA 的主要和次要轴),(iii)PRL 子午线(极角)和(iv)PRL 偏心度。使用 Bland-Altman 图评估每个参数的测试-重测重复性,以确定 95%一致性界限。
固视试验对之间的平均差异和 95%一致性界限为固视点稳定性、PRL 主要轴、PRL 次要轴、PRL 子午线和 PRL 偏心度分别为 0.06±0.47 log deg、0.05°±1.42°、0.07°±0.63°、-0.44°±66.0°和-0.23°±1.56°。
WE 的固视参数表现出稳健的可重复性,与之前研究中确定的 BE 相当。在解释治疗干预后固视结果测量值时,应考虑 WE 的固视重复性。