基于垂直跳跃力-时间特征的便携式测力台的同时效度

Concurrent Validity of a Portable Force Plate Using Vertical Jump Force-Time Characteristics.

作者信息

Lake Jason, Mundy Peter, Comfort Paul, McMahon John J, Suchomel Timothy J, Carden Patrick

机构信息

1 University of Chichester.

2 Coventry University.

出版信息

J Appl Biomech. 2018 Oct 1;34(5):410-413. doi: 10.1123/jab.2017-0371. Epub 2018 Oct 11.

Abstract

This study examined concurrent validity of countermovement vertical jump reactive strength index modified and force-time characteristics recorded using a 1-dimensional portable and laboratory force plate system. Twenty-eight men performed bilateral countermovement vertical jumps on 2 portable force plates placed on top of 2 in-ground force plates, both recording vertical ground reaction force at 1000 Hz. Time to takeoff; jump height; reactive strength index modified; and braking and propulsion impulse, mean net force, and duration were calculated from the vertical force from both force plate systems. Results from both systems were highly correlated (r ≥ .99). There were small (d < 0.12) but significant differences between their respective braking impulse, braking mean net force, propulsion impulse, and propulsion mean net force (P < .001). However, limits of agreement yielded a mean value of 1.7% relative to the laboratory force plate system (95% confidence limits, 0.9%-2.5%), indicating very good agreement across all of the dependent variables. The largest limits of agreement were for jump height (2.1%), time to takeoff (3.4%), and reactive strength index modified (3.8%). The portable force plate system provides a valid method of obtaining reactive strength measures, and several underpinning force-time variables, from unloaded countermovement vertical jump. Thus, practitioners can use both force plates interchangeably.

摘要

本研究考察了使用一维便携式和实验室测力台系统记录的改良反向纵跳反应力量指数及力-时间特征的同时效度。28名男性在放置于两个地面测力台上的两个便携式测力台上进行双侧反向纵跳,两个测力台均以1000Hz记录垂直地面反作用力。根据两个测力台系统的垂直力计算起跳时间、跳跃高度、改良反应力量指数以及制动和推进冲量、平均净力和持续时间。两个系统的结果高度相关(r≥0.99)。它们各自的制动冲量、制动平均净力、推进冲量和推进平均净力之间存在微小(d<0.12)但显著的差异(P<0.001)。然而,一致性界限相对于实验室测力台系统产生的平均值为1.7%(95%置信区间,0.9%-2.5%),表明所有因变量之间具有非常好的一致性。最大的一致性界限出现在跳跃高度(2.1%)、起跳时间(3.4%)和改良反应力量指数(3.8%)上。便携式测力台系统提供了一种从无负重反向纵跳中获取反应力量测量值以及几个基础力-时间变量的有效方法。因此,从业者可以互换使用这两种测力台。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验