Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.
Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.
J Endod. 2018 Aug;44(8):1289-1292. doi: 10.1016/j.joen.2018.04.011. Epub 2018 Jun 19.
The purpose of this study was to evaluate apical debris extrusion associated with different kinematics in curved root canals.
Forty-five extracted mandibular molars with root curvature angles ranging between 20° and 40° and curvature radii <10 mm were randomly assigned to 3 groups (n = 15) according to the kinematics used for root canal preparation: reciprocating motion with the WaveOne Gold system (Dentsply Tulsa Dental, Tulsa, OK), rotary/reciprocating motion with the Twisted File Adaptive system (SybronEndo, Orange, CA), and the manual technique. The debris apically extruded during preparation was collected into preweighed Eppendorf tubes. The tubes were then stored in an incubator at 70°C for 5 days. The extruded debris was quantified by subtracting the preinstrumentation from the postinstrumentation weight of the Eppendorf tubes. The time required for each instrumentation procedure was recorded. Data were analyzed using 1-way analysis of variance Tukey post hoc tests (∝ = 0.05).
The WaveOne Gold reciprocating single-file system was associated with less extrusion of debris compared with hand files (P < .05) and the Twisted File Adaptive system (P > .05). The preparation time required by hand files was significantly longer than that required by the other techniques (P < .05).
Under the conditions of this study, all of the instrumentation systems caused apical debris extrusion to some degree. The WaveOne Gold reciprocating system was associated with less debris extrusion in curved root canals compared with the manual technique and the Twisted File Adaptive system although the difference between the WaveOne Gold and Twisted File Adaptive systems was not significant.
本研究的目的是评估不同根管预备运动学条件下与根尖碎屑挤出相关的问题。
将 45 颗下颌磨牙随机分为 3 组(每组 15 颗),根据根管预备运动学分组:WaveOne Gold 系统(登士柏特兰,塔尔萨,OK)的往复运动、Twisted File Adaptive 系统(登士柏 SybronEndo,橙,CA)的旋转/往复运动和手动技术。在预备过程中,根尖挤出的碎屑被收集到预称重的 Eppendorf 管中。然后将管储存在 70°C 的孵育箱中 5 天。通过从 Eppendorf 管的预仪器化重量中减去后仪器化重量来定量挤出的碎屑。记录每个仪器化程序所需的时间。使用单向方差分析 Tukey 事后检验(∝=0.05)分析数据。
WaveOne Gold 往复单文件系统与手用锉相比,产生的碎屑挤出量较少(P<.05),与 Twisted File Adaptive 系统(P>.05)相比,差异无统计学意义。手用锉的预备时间明显长于其他技术(P<.05)。
在本研究条件下,所有器械系统都在某种程度上导致根尖碎屑挤出。与手动技术和 Twisted File Adaptive 系统相比,WaveOne Gold 往复系统在弯曲根管中产生的碎屑挤出量较少,尽管 WaveOne Gold 和 Twisted File Adaptive 系统之间的差异无统计学意义。