Compare word recognition scores for adults undergoing cochlear implant evaluations (CIE) measured using earphones and hearing aids.
Retrospective review of data obtained during adult CIEs.
Tertiary cochlear implant center.
Two hundred eight ears in 183 subjects with greater than 10% word recognition scores measured with earphones.
INTERVENTIONS/MAIN OUTCOMES MEASURED: Preoperative pure-tone thresholds and word recognition scores measured with earphones and hearing aids.
A review of audiological data obtained from 2012 to 2017 during adult CIEs was conducted. Overall, a weak positive correlation (r = 0.33, 95% confidence interval 0.17-0.40, p < 0.001) was observed between word recognition scores measured with earphones and hearing aids. Earphone to aided differences (EAD) ranged from -38 to +72% (mean 14.3 ± 19.9%). Consistent with EADs, 108 ears (51.9%) had earphone scores that were significantly higher than aided word recognition scores (+EAD), as determined by 95% confidence intervals; for 14 ears (6.7%), earphone scores were significantly lower than aided scores (-EAD). Moreover, of the patients with earphone word recognition scores ≥50%, 82.6% were CI candidates based on aided AzBio+10 dB SNR scores.
These results demonstrate the limited diagnostic value of word recognition scores measured under earphones for patients undergoing CIE. Nevertheless, aided word recognition is rarely measured before CIEs, which limits the information available to determine CI candidacy and referral for CIEs. Earlier and routine measurement of aided word recognition may help guide clinical decision making by determining the extent to which patients are achieving maximum benefit with their hearing aids or should consider cochlear implantation.
比较使用耳机和助听器对接受人工耳蜗植入评估(CIE)的成年人进行的单词识别分数。
对成人 CIE 期间获得的数据进行回顾性审查。
三级人工耳蜗植入中心。
183 名患者中有 208 只耳朵的单词识别分数大于 10%,使用耳机测量。
干预/主要观察结果:使用耳机和助听器测量的术前纯音阈值和单词识别分数。
对 2012 年至 2017 年期间成人 CIE 期间获得的听力学数据进行了回顾。总体而言,耳机和助听器测量的单词识别分数之间观察到微弱的正相关(r=0.33,95%置信区间 0.17-0.40,p<0.001)。耳机到辅助的差异(EAD)范围为-38 至+72%(平均值 14.3±19.9%)。与 EAD 一致,108 只耳朵(51.9%)的耳机分数明显高于辅助单词识别分数(+EAD),95%置信区间确定;对于 14 只耳朵(6.7%),耳机分数明显低于辅助分数(-EAD)。此外,在具有≥50%耳机单词识别分数的患者中,根据辅助 AzBio+10dB SNR 分数,82.6%是人工耳蜗植入的候选者。
这些结果表明,在接受人工耳蜗植入的患者中,使用耳机测量的单词识别分数的诊断价值有限。尽管如此,在人工耳蜗植入前很少测量辅助单词识别,这限制了确定人工耳蜗植入候选者和转诊的可用信息。更早和常规测量辅助单词识别可能有助于通过确定患者从助听器中获得最大受益的程度或应考虑人工耳蜗植入来指导临床决策。