Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Turku, Finland; Department of Prosthetic Dentistry, Institute of Dentistry, University of Eastern Finland, Kuopio, Finland; Adhesive Dentistry Research Group, Biomaterials and Medical Device Research Programme, Biocity, Turku, Finland.
J Mech Behav Biomed Mater. 2018 Oct;86:14-22. doi: 10.1016/j.jmbbm.2018.06.015. Epub 2018 Jun 8.
To evaluate whether selective dentin etching protocols using reduced phosphoric acid (HPO) etching-times would affect the resin-dentin interaction of a universal adhesive to improve long-term bonding effectiveness.
Mid-coronal flat dentin surfaces were produced on sound third molars, selectively etched with 32% HPO for 3, 5, 10 or 15 s and bonded with a universal adhesive (Scotchbond Universal, 3 M ESPE: SU). SU in self-etch mode and a three-step etch-and-rinse adhesive were used as control groups. Bonded specimens were stored in deionized water for 24 h and sectioned into beams (cross sectional area of 0.7 mm). Micro-tensile bond strength test (n = 6) and nanoleakage evaluation were performed immediately, after thermocycling or 6-month storage in artificial saliva. Energy dispersive X-ray analysis (n = 6) was performed to determine the residual Ca-content ratio at the hybrid layers and scanning electron microscopy (SEM) was used to observe the micromorphology of the etched dentin surfaces before and after SU application. Data were analyzed by ANOVA and Tukey test (α = 0.05).
Selective dentin etching for 3 s improved the interaction depth of the tested universal adhesive without overexposing demineralized collagen or reducing Ca-content availability at the bonded interface. The improved immediate bond strengths of the selective etching protocol remained significantly higher (p < 0.05) after long-term aging producing hybrid layers without significant differences (p > 0.05) in silver uptake levels compared to those produced on non-etched dentin.
Despite the adjunctive conclusion that universal adhesives used in self-etch mode produce superior long-term dentin bonding compared to the etch-and-rinse mode, selective etching for 3 s with conventionally used HPO improves dentin bonding effectiveness; nonetheless, longer etching times should be strictly avoided.
评估使用减少的磷酸(HPO)蚀刻时间的选择性牙本质蚀刻方案是否会影响通用粘结剂的树脂-牙本质粘结,以提高长期粘结效果。
在健康的第三磨牙的近中冠状平面牙本质表面上产生,用 32%的 HPO 选择性蚀刻 3、5、10 或 15 秒,并用通用粘结剂(Scotchbond Universal,3M ESPE:SU)粘结。SU 自酸蚀模式和三步酸蚀-冲洗粘结剂作为对照组。粘结试件在去离子水中储存 24 小时,然后切成梁(横截面积为 0.7mm)。立即进行微拉伸粘结强度测试(n=6)和纳米渗漏评估,然后进行热循环或在人工唾液中储存 6 个月后进行。进行能量色散 X 射线分析(n=6)以确定混合层的残留 Ca 含量比,并使用扫描电子显微镜(SEM)观察 SU 应用前后牙本质表面的微观形态。数据采用 ANOVA 和 Tukey 检验(α=0.05)进行分析。