Suppr超能文献

多模式黏附系统的黏附性能:1年体外研究

Adhesive performance of a multi-mode adhesive system: 1-year in vitro study.

作者信息

Marchesi Giulio, Frassetto Andrea, Mazzoni Annalisa, Apolonio Fabianni, Diolosà Marina, Cadenaro Milena, Di Lenarda Roberto, Pashley David H, Tay Franklin, Breschi Lorenzo

机构信息

Department of Medical Sciences, University of Trieste, Trieste, Italy.

Department of Dentistry, Universidade Federal Do Ceara, Fortaleza, Brazil.

出版信息

J Dent. 2014 May;42(5):603-12. doi: 10.1016/j.jdent.2013.12.008. Epub 2013 Dec 25.

Abstract

OBJECTIVES

The aim of this study was to investigate the adhesive stability over time of a multi-mode one-step adhesive applied using different bonding techniques on human coronal dentine. The hypotheses tested were that microtensile bond strength (μTBS), interfacial nanoleakage expression and matrix metalloproteinases (MMPs) activation are not affected by the adhesive application mode (following the use of self-etch technique or with the etch-and-rinse technique on dry or wet dentine) or by ageing for 24h, 6 months and 1year in artificial saliva.

METHODS

Human molars were cut to expose middle/deep dentine and assigned to one of the following bonding systems (N=15): (1) Scotchbond Universal (3M ESPE) self-etch mode, (2) Scotchbond Universal etch-and-rinse technique on wet dentine, (3) Scotchbond Universal etch-and-rinse technique on dry dentine, and (4) Prime&Bond NT (Dentsply De Trey) etch-and-rinse technique on wet dentine (control). Specimens were processed for μTBS test in accordance with the non-trimming technique and stressed to failure after 24h, 6 months or 1 year. Additional specimens were processed and examined to assay interfacial nanoleakage and MMP expression.

RESULTS

At baseline, no differences between groups were found. After 1 year of storage, Scotchbond Universal applied in the self-etch mode and Prime&Bond NT showed higher μTBS compared to the other groups. The lowest nanoleakage expression was found for Scotchbond Universal applied in the self-etch mode, both at baseline and after storage. MMPs activation was found after application of each tested adhesive.

CONCLUSIONS

The results of this study support the use of the self-etch approach for bonding the tested multi-mode adhesive system to dentine due to improved stability over time.

CLINICAL SIGNIFICANCE

Improved bonding effectiveness of the tested universal adhesive system on dentine may be obtained if the adhesive is applied with the self-etch approach.

摘要

目的

本研究旨在调查使用不同粘结技术在人牙冠部牙本质上应用的多模式一步法粘结剂随时间的粘结稳定性。所检验的假设为,微拉伸粘结强度(μTBS)、界面纳米渗漏表现和基质金属蛋白酶(MMPs)激活不受粘结剂应用模式(在使用自酸蚀技术后,或在干燥或湿润牙本质上使用酸蚀冲洗技术)或在人工唾液中老化24小时、6个月和1年的影响。

方法

将人类磨牙切割以暴露中/深层牙本质,并分配到以下粘结系统之一(N = 15):(1)Scotchbond Universal(3M ESPE)自酸蚀模式,(2)Scotchbond Universal在湿润牙本质上的酸蚀冲洗技术,(3)Scotchbond Universal在干燥牙本质上的酸蚀冲洗技术,以及(4)Prime&Bond NT(登士柏西诺德)在湿润牙本质上的酸蚀冲洗技术(对照)。按照非修整技术对样本进行μTBS测试处理,并在24小时、6个月或1年后施加应力直至破坏。对额外的样本进行处理和检查,以测定界面纳米渗漏和MMP表达。

结果

在基线时,各组之间未发现差异。储存1年后,以自酸蚀模式应用的Scotchbond Universal和Prime&Bond NT相比其他组显示出更高的μTBS。在基线和储存后,以自酸蚀模式应用的Scotchbond Universal的纳米渗漏表现最低。在应用每种测试粘结剂后均发现了MMPs激活。

结论

本研究结果支持使用自酸蚀方法将测试的多模式粘结系统粘结至牙本质,因为随着时间推移稳定性得到改善。

临床意义

如果使用自酸蚀方法应用粘结剂,可能会提高测试的通用粘结系统在牙本质上的粘结效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验