Delany H M, Rudavsky A Z, Lan S
J Trauma. 1985 Sep;25(9):909-13. doi: 10.1097/00005373-198509000-00016.
Splenorrhaphy was performed in six patients using absorbable polyglycolic acid mesh. The sustained injuries included blunt and penetrating trauma and varied from through-and-through puncture with hematoma and deep lacerations to amputation of a portion of the spleen. A number of different splenorrhaphy techniques were required. In all six cases, the procedure was accomplished without abscess formation, postoperative bleeding, or complications related to the use of the mesh.