Yoshikawa Yuji, Shoji Takuhei, Kanno Junji, Kimura Itaru, Hangai Masanori, Shinoda Kei
Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
Hangai Eye Institute, Saitama, Japan.
Clin Ophthalmol. 2018 Jun 19;12:1113-1119. doi: 10.2147/OPTH.S167222. eCollection 2018.
To evaluate the ability of enhanced-depth imaging (EDI) optical coherence tomography angiography (OCTA) to detect vascular signals inside the glaucomatous optic disc.
Ten glaucomatous eyes of 8 subjects and 11 nonglaucomatous eyes of 7 subjects underwent EDI and conventional OCTA for optic disc analysis. The optic disc vessel density (VD) at maximum scan depth (2 mm) was compared between the 2 methods and between glaucomatous and nonglaucomatous eyes. Regression analysis was used to determine the factors affecting disc VD.
The median (25th, 75th percentile) of the visual field mean deviation was -20.5 (-25.1, -13.5) dB in glaucoma. The disc VD measured with the EDI method was significantly greater than that measured with the conventional method in glaucoma and nonglaucoma. The disc VD was also significantly lower in glaucoma than in nonglaucoma. The disc VD and mean deviation were significantly and positively correlated in both methods (conventional: =0.27, EDI: =0.22).
The correlation between disc VD and glaucoma severity was comparable between conventional and EDI measurements. Images obtained with EDI-OCTA have the additional benefit of revealing more vascular signals in deeper layers. The disc VD, as determined by both conventional and EDI-OCTA methods, may be an indicator of glaucoma severity.
评估增强深度成像(EDI)光学相干断层扫描血管造影(OCTA)检测青光眼性视盘内血管信号的能力。
对8名受试者的10只青光眼眼和7名受试者的11只非青光眼眼进行EDI和传统OCTA检查以分析视盘。比较两种方法之间以及青光眼眼和非青光眼眼之间在最大扫描深度(2mm)处的视盘血管密度(VD)。采用回归分析确定影响视盘VD的因素。
青光眼患者视野平均缺损的中位数(第25、75百分位数)为-20.5(-25.1,-13.5)dB。在青光眼和非青光眼患者中,用EDI方法测量的视盘VD显著大于用传统方法测量的视盘VD。青光眼患者的视盘VD也显著低于非青光眼患者。两种方法中视盘VD与平均缺损均呈显著正相关(传统方法:=0.27,EDI方法:=0.22)。
传统测量和EDI测量中视盘VD与青光眼严重程度之间的相关性相当。用EDI-OCTA获得的图像还有在更深层揭示更多血管信号的额外优势。通过传统方法和EDI-OCTA方法确定的视盘VD可能是青光眼严重程度的一个指标。