Suppr超能文献

种植体周围组织的 5 年轮廓测量变化:一项比较单/两段式种植体系统的随机对照试验。

Profilometric changes of peri-implant tissues over 5 years: A randomized controlled trial comparing a one- and two-piece implant system.

机构信息

Clinic of Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.

Discipline of Periodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil.

出版信息

Clin Oral Implants Res. 2018 Aug;29(8):864-872. doi: 10.1111/clr.13308. Epub 2018 Jun 27.

Abstract

OBJECTIVES

To assess the profilometric changes of the buccal soft tissues between baseline and 5 years of loading using a one- and two-piece dental implant system.

MATERIALS AND METHODS

Sixty patients randomly received dental implants of either a two-piece type (BRA) or a one-piece type (STM). Casts were obtained at baseline (after crown insertion), at the 1-year and at the 5-year follow-up. Stereolithography files were obtained from the casts for digital superimposition. One implant and the contralateral natural tooth were selected for the analysis. Thirty-three patients (BRA = 16; STM = 17) were included. Measurements included changes for crown height (CH) and estimated soft tissue thickness, as well as the profilometric change at the implant and the tooth site. Nonparametric methods were applied for the statistical analyses and medians and quartiles presented.

RESULTS

The BRA group lost -0.39 mm and the STM group lost -0.40 mm of volume between baseline and the 5-year follow-up at the implant site (p > 0.05). The tooth site lost -0.18 mm (BRA) and -0.12 mm (STM) (p > 0.05). Volume differences between implants and teeth amounted to -0.05 mm (baseline to 1 year) and -0.25 mm (baseline to 5 years) for BRA, while for STM, the values were 0.03 mm (baseline to 1 year) and -0.16 mm (baseline to 5 years). The changes for implant CH at 1 and 5 years of follow-up amounted 0.10 and 0.09 mm (BRA) and to 0.03 and 0.22 mm (STM). The changes in tissue thickness at 1 and 5 years in the BRA group amounted to -0.28 and -0.66 mm at 1 mm, -0.21 and -0.46 mm at 3 mm, and -0.32 and -0.45 mm at 5 mm, respectively. The changes in the STM group amounted to -0.15 and -0.54 mm at 1 mm, -0.24 and -0.48 mm at 3 mm, and -0.32 and -0.57 mm at 5 mm, respectively. No significantly different medians were observed.

CONCLUSIONS

Minimal profilometric and linear changes occurred at implant sites between baseline and 5 years, between implant and tooth sites and between the two implant systems.

摘要

目的

使用两段式和一段式牙科种植体系统评估颊部软组织在基线和 5 年负荷下的轮廓变化。

材料和方法

60 名患者随机接受两段式种植体(BRA)或一段式种植体(STM)治疗。在基线(牙冠插入后)、1 年和 5 年随访时获得印模。从印模中获得立体光刻文件以进行数字叠加。选择一个种植体和对侧天然牙进行分析。33 名患者(BRA=16;STM=17)入选。测量包括牙冠高度(CH)和估计软组织厚度的变化,以及种植体和牙齿部位的轮廓变化。采用非参数方法进行统计学分析,给出中位数和四分位数。

结果

BRA 组种植体部位在基线和 5 年随访期间损失了-0.39mm,STM 组损失了-0.40mm(p>0.05)。牙体部位 BRA 组损失了-0.18mm,STM 组损失了-0.12mm(p>0.05)。种植体和牙齿之间的体积差异分别为 BRA 组-0.05mm(基线至 1 年)和-0.25mm(基线至 5 年),而 STM 组分别为 0.03mm(基线至 1 年)和-0.16mm(基线至 5 年)。1 年和 5 年随访时种植体 CH 的变化分别为 BRA 组 0.10mm 和 0.09mm,以及 STM 组 0.03mm 和 0.22mm。BRA 组在 1 年和 5 年时的组织厚度变化分别为 1mm 处-0.28mm 和-0.66mm,3mm 处-0.21mm 和-0.46mm,5mm 处-0.32mm 和-0.45mm。STM 组在 1 年和 5 年时的变化分别为 1mm 处-0.15mm 和-0.54mm,3mm 处-0.24mm 和-0.48mm,5mm 处-0.32mm 和-0.57mm。未观察到显著差异的中位数。

结论

在基线和 5 年内,两段式和一段式种植体系统的种植体部位、种植体和牙齿部位以及两种种植体系统之间仅发生微小的轮廓和线性变化。