Research and Development, Orion Diagnostica Oy, P. O. BOX 83, 02101, Espoo, Finland.
Mol Diagn Ther. 2018 Oct;22(5):595-602. doi: 10.1007/s40291-018-0346-8.
Streptococcus pyogenes (group A Streptococcus, GAS) is responsible for a variety of highly communicable infections, accounting for 5-15 and 20-30% of sore throat hospital visits in adults and children, respectively. Prompt diagnosis of GAS can improve the quality of patient care and minimize the unnecessary use of antibiotics.
Our objective was to develop an alternative nucleic acid amplification method for the diagnosis of GAS.
We developed and evaluated a strand invasion based amplification (SIBA) assay to rapidly and specifically detect GAS. The performance of the developed GAS SIBA assay was compared with an established GAS polymerase chain reaction (PCR) assay.
The GAS SIBA assay detected small amounts (ten copies) of S. pyogenes DNA within 13 min. The rapid detection time was achieved in part by optimization of magnesium concentration and reaction temperature. The sensitivity and specificity of the GAS SIBA assay for detection of S. pyogenes from clinical specimens were both 100%, and clinical specimens were detected within ~ 8 min of starting the reaction.
Because the GAS SIBA assay is performed at low and constant temperature, it can be used both in centralized laboratories and for point-of-care testing. Furthermore, given its short detection time and strong analytical performance, the GAS SIBA assay could help to improve patient care and minimize unnecessary prescription of antibiotics.
化脓性链球菌(A 组链球菌,GAS)可引起多种高度传染性感染,分别占成人和儿童咽痛住院就诊的 5-15%和 20-30%。及时诊断 GAS 可提高患者护理质量,并最大限度减少不必要的抗生素使用。
我们旨在开发一种用于 GAS 诊断的替代核酸扩增方法。
我们开发并评估了一种基于链入侵的扩增(SIBA)检测方法,用于快速且特异性地检测 GAS。与已建立的 GAS 聚合酶链反应(PCR)检测相比,我们比较了开发的 GAS SIBA 检测的性能。
GAS SIBA 检测法在 13 分钟内即可检测到少量(十拷贝)的化脓性链球菌 DNA。通过优化镁浓度和反应温度,实现了快速检测时间。GAS SIBA 检测法检测临床标本中化脓性链球菌的灵敏度和特异性均为 100%,反应开始后 8 分钟内即可检测到临床标本。
由于 GAS SIBA 检测法在低温和恒温和条件下进行,因此既可以在集中式实验室中使用,也可以用于即时护理检测。此外,鉴于其较短的检测时间和较强的分析性能,GAS SIBA 检测法有助于改善患者护理,并最大限度减少不必要的抗生素处方。