J Arthroplasty. 2018 Oct;33(10):3320-3324. doi: 10.1016/j.arth.2018.06.003. Epub 2018 Jun 13.
Cross-linked polyethylene (XLPE) has generally low rates of wear and osteolysis at 10 years, but component position may become important with longer follow-up. At 5-13 years, neither acetabular component lateral opening angle nor version were significantly correlated to wear. In the present study, we analyzed the effects of femoral anteversion and combined anteversion on XLPE wear.
Forty-two well-functioning primary total hip arthroplasties in 36 patients, performed by a single surgeon via a posterior approach, were followed for a minimum of 5 years (mean, 7.1 years; range, 5.0-10.3). All hips had a modular, XLPE liner with a ≥36-mm bearing. Femoral anteversion was measured on the modified Budin view. Wear was measured on radiographs using a validated, computer-assisted, edge-detection-based algorithm. The mean lateral opening angle was 40.4° (range, 22.6°-50.3°). The mean acetabular version was 19.1° (range, 11.3°-27.5°). Neither of these variables was significantly correlated to wear. Effects of femoral anteversion and combined anteversion on XLPE wear were assessed using linear and polynomial regression analysis.
Femoral anteversion (mean, 18.4°; range, 6.8°-30.7°) was significantly correlated to linear wear (mean, 0.06 mm/y; range, 0-0.16), showing an inverse parabolic relationship with the least wear occurring at 18.2° (P = .02). Combined anteversion (mean, 37.2°; range, 21.8°-54.3°) showed a similar significant relationship with the least wear at 38.1° (P < .001). Based on regression, combined anteversion between 24.6° and 50.4° resulted in linear wear rates less than 0.1 mm/y.
To the authors' knowledge, this is the first study to identify femoral anteversion as an independent factor influencing XLPE wear, with least wear occurring around 18°. At 5-10 years, average linear wear of XLPE is below 0.1 mm/y over a 25°-50° range of combined anteversion, with the least wear around 38°. Femoral-acetabular mating is a product of both components. Femoral component version and combined anteversion had a greater effect on wear than acetabular component lateral opening angle. Additional studies are warranted, but these results indicate that the sensitivity of wear studies is increased with version assessments.
交联聚乙烯(XLPE)在 10 年内通常具有较低的磨损和骨质溶解率,但随着随访时间的延长,部件位置可能变得重要。在 5-13 年内,髋臼部件外侧开口角度和版本均与磨损无显著相关性。在本研究中,我们分析了股骨前倾角和组合前倾角对 XLPE 磨损的影响。
对 36 名患者的 42 例初次全髋关节置换术后进行了至少 5 年(平均 7.1 年;范围 5.0-10.3 年)的随访。所有髋关节均采用后路入路,由同一位外科医生进行了模块化、XLPE 衬垫,具有≥36mm 的轴承。股骨前倾角在改良 Budin 视图上测量。使用经过验证的、基于计算机辅助的边缘检测算法在 X 光片上测量磨损。平均外侧开口角度为 40.4°(范围 22.6°-50.3°)。平均髋臼版本为 19.1°(范围 11.3°-27.5°)。这两个变量均与磨损无显著相关性。使用线性和多项式回归分析评估股骨前倾角和组合前倾角对 XLPE 磨损的影响。
股骨前倾角(平均 18.4°;范围 6.8°-30.7°)与线性磨损显著相关(平均 0.06mm/y;范围 0-0.16),呈反抛物线关系,在 18.2°时磨损最少(P=0.02)。组合前倾角(平均 37.2°;范围 21.8°-54.3°)与 38.1°时的最小磨损具有相似的显著关系(P<0.001)。基于回归,组合前倾角在 24.6°至 50.4°之间导致线性磨损率低于 0.1mm/y。
据作者所知,这是第一项确定股骨前倾角为影响 XLPE 磨损的独立因素的研究,在 18°左右时磨损最少。在 5-10 年内,在 25°-50°的组合前倾角范围内,XLPE 的平均线性磨损低于 0.1mm/y,在 38°左右时磨损最少。股骨-髋臼匹配是两个部件的产物。髋臼部件外侧开口角度和组合前倾角对磨损的影响大于股骨部件版本。需要进一步研究,但这些结果表明,通过评估版本,可以提高磨损研究的敏感性。