生物电阻抗分析在测量四肢骨骼肌质量/全身脂肪质量中的应用及其在评估腰痛患者骨质疏松症中的相关性:使用双能X线吸收法的比较分析

Use of Bioelectrical Impedance Analysis for the Measurement of Appendicular Skeletal Muscle Mass/Whole Fat Mass and Its Relevance in Assessing Osteoporosis among Patients with Low Back Pain: A Comparative Analysis Using Dual X-ray Absorptiometry.

作者信息

Fujimoto Kazuki, Inage Kazuhide, Eguchi Yawara, Orita Sumihisa, Suzuki Miyako, Kubota Go, Sainoh Takeshi, Sato Jun, Shiga Yasuhiro, Abe Koki, Kanamoto Hirohito, Inoue Masahiro, Kinoshita Hideyuki, Norimoto Masaki, Umimura Tomotaka, Koda Masao, Furuya Takeo, Akazawa Tsutomu, Toyoguchi Toru, Terakado Atsushi, Takahashi Kazuhisa, Ohtori Seiji

机构信息

Department of Orthopaedic Surgery, Chibaken Saiseikai Narashino Hospital, Narashino, Japan.

Department of Orthopaedic Surgery, Chiba University Graduate School of Medicine, Chiba, Japan.

出版信息

Asian Spine J. 2018 Oct;12(5):839-845. doi: 10.31616/asj.2018.12.5.839. Epub 2018 Sep 10.

Abstract

STUDY DESIGN

Cross-sectional observational study.

PURPOSE

To compare measurements of appendicular skeletal muscle mass (ASMM) and whole fat mass (WFM) obtained using dualenergy X-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA) among patients with low back pain (LBP). Moreover, the study investigated the correlation between BIA-based ASMM and DXA-based bone mineral density (BMD). Overview of the Literature: If reliable, BIA may be a useful alternative to DXA as a screening tool for sarcopenia and osteoporosis among patients with LBP.

METHODS

Measurements were performed in 130 patients, including BMD of the lumbar spine and femoral neck. The correlation between DXA and BIA as well as between BIA-ASMM and BMD were evaluated.

RESULTS

BIA and DXA were highly correlated in both male and female patients (r =0.73-0.90, p <0.0001). However, BIA consistently overestimated ASMM by 1.5-2.5 kg on an average (p <0.0001) and underestimated WFM (-4.0 to -2.7 kg) on an average (p <0.0001). BIA-based ASMM correlated with BMD of the lumbar spine in both male and female patients (r =0.28-0.37, p ≤0.02) and that of the femoral neck (r =0.34-0.51, p ≤0.005). Regarding the calculated skeletal muscle index (SMI: ASMM/height [m2]) used as a criterion for sarcopenia, BIA-based SMI correlated with BMD of the lumbar spine in male patients (r =0.44, p =0.0004) and that of the femoral neck in female patients (r =0.33, p =0.009).

CONCLUSIONS

BIA may be a favorable alternative to DXA as a screening tool for sarcopenia and osteoporosis among patients with LBP. Considering the overestimation of BIA-based ASMM and SMI, we recommend using the cutoff values for sarcopenia of 7.9 kg/m2 for males and 6.1 kg/m2 for females.

摘要

研究设计

横断面观察性研究。

目的

比较在腰痛(LBP)患者中使用双能X线吸收法(DXA)和生物电阻抗分析(BIA)获得的四肢骨骼肌质量(ASMM)和全身脂肪质量(WFM)的测量值。此外,该研究调查了基于BIA的ASMM与基于DXA的骨密度(BMD)之间的相关性。文献综述:如果可靠,BIA可能是DXA的一种有用替代方法,可作为LBP患者肌肉减少症和骨质疏松症的筛查工具。

方法

对130例患者进行测量,包括腰椎和股骨颈的骨密度。评估了DXA与BIA之间以及基于BIA的ASMM与BMD之间的相关性。

结果

BIA和DXA在男性和女性患者中均高度相关(r = 0.73 - 0.90,p < 0.0001)。然而,BIA平均持续高估ASMM 1.5 - 2.5 kg(p < 0.0001),平均低估WFM(-4.0至-2.7 kg)(p < 0.0001)。基于BIA的ASMM在男性和女性患者中均与腰椎骨密度相关(r = 0.28 - 0.37,p≤0.02)以及与股骨颈骨密度相关(r = 0.34 - 0.51,p≤0.005)。关于用作肌肉减少症标准的计算骨骼肌指数(SMI:ASMM/身高[m2]),基于BIA的SMI在男性患者中与腰椎骨密度相关(r = 0.44,p = 0.0004),在女性患者中与股骨颈骨密度相关(r = 0.33,p = 0.009)。

结论

BIA可能是DXA的一种有利替代方法,可作为LBP患者肌肉减少症和骨质疏松症的筛查工具。考虑到基于BIA的ASMM和SMI的高估,我们建议男性肌肉减少症的临界值为7.9 kg/m2,女性为6.1 kg/m2。