Abstract

BACKGROUND

Glenoid loosening, a common complication of shoulder arthroplasty, could relate to implant design and bone quality. However, the role of bone density has not been tested experimentally yet. In this study, tests on cadaveric specimens of varying bone density were performed to evaluate the effects of bone quality on loosening of typical anatomic glenoid implants.

METHODS

Cadaveric scapulae scanned with a quantitative computed tomography scanner to determine bone mineral density (BMD) were implanted with either pegged or keeled cemented glenoid components and tested under constant glenohumeral load while a humeral head component was moved cyclically in the inferior and superior directions. Implant superior and inferior edge lifting, defined as displacement from the underlying bone, was measured with linear variable differential transducers until we reached 23,000 test cycles, and statistical testing was performed for differences in edge lifting due to implant design and related to periprosthetic BMD.

RESULTS

Edge lifting was statistically significant at all time points, but on average, implant design had no effect. Lifting was highest in specimens in which BMD below the lifting edge was lower, with trends of increased displacement with decreased BMD.

CONCLUSIONS

Implant lifting was greater in glenoids of lower bone density for both implant designs. This finding suggests that fixation failure will most likely occur in bone of lower density and that the fixation design itself may play a secondary role.

摘要

背景

肩关节炎置换术后常见的并发症是肩胛盂松动,这可能与植入物设计和骨质量有关。然而,骨密度的作用尚未经过实验验证。在这项研究中,对不同骨密度的尸体标本进行了测试,以评估骨质量对典型解剖肩胛盂植入物松动的影响。

方法

使用定量计算机断层扫描(CT)扫描仪对肩胛骨进行扫描,以确定骨矿物质密度(BMD),然后将肩胛盂植入物用带钉或带嵴的骨水泥固定,并在恒定的盂肱负荷下进行测试,同时使肱骨头组件在下方和上方方向周期性移动。使用线性可变差动传感器测量植入物上、下边缘抬升,定义为从下骨表面的位移,直到达到 23000 个测试周期,然后对由于植入物设计和与假体周围 BMD 相关的边缘抬升差异进行统计学检验。

结果

在所有时间点,边缘抬升均具有统计学意义,但平均而言,植入物设计没有影响。在抬起边缘下方 BMD 较低的标本中,抬升幅度最大,随着 BMD 的降低,位移趋势增加。

结论

对于两种植入物设计,骨密度较低的肩胛盂植入物的抬升幅度更大。这一发现表明,固定失败最有可能发生在骨密度较低的区域,而固定设计本身可能发挥次要作用。