Suppr超能文献

DMEK术后视觉质量和角膜结构的早期变化:DMEK能否达到健康角膜的光学质量?

Early Changes in Visual Quality and Corneal Structure after DMEK: Does DMEK Approach Optical Quality of a Healthy Cornea?

作者信息

Satue Maria, Idoipe Miriam, Gavin Alicia, Romero-Sanz Maria, Liarakos Vasilios S, Mateo Antonio, Garcia-Martin Elena, Blasco-Martinez Alejandro, Sanchez-Perez Antonio

机构信息

IIS-Aragon, Aragon Institute for Health Research (IIS Aragón), Zaragoza, Spain.

Ophthalmology Department, Miguel Servet University Hospital, Zaragoza, Spain.

出版信息

J Ophthalmol. 2018 Sep 23;2018:2012560. doi: 10.1155/2018/2012560. eCollection 2018.

Abstract

PURPOSE

To evaluate early changes in visual function and visual quality parameters after Descemet membrane endothelial keratoplasty (DMEK) and to compare the outcomes with healthy controls.

METHODS

Thirteen patients who underwent DMEK and 14 controls were evaluated. All subjects underwent visual function evaluation, including visual acuity under photopic and mesopic lighting conditions and contrast sensitivity (CSV) tests CSV 1000 and Pelli-Robson. Corneal parameters were assessed with Oculus Pentacam. Corneal mean keratometry (Km), corneal densitometry values, and low and high order aberrations (LOA and HOA) were recorded. In DMEK patients, all tests were performed before surgery and 1 and 6 months after surgery.

RESULTS

In patients who underwent DMEK, photopic visual acuity improved from 0.59 to 0.31 at 1 month (=0.013) and 0.13 at 6 months (=0.008); mesopic visual acuity and all contrast sensitivity values (both CSV and Pelli-Robson test) improved significantly in the first month ( < 0.005). A significant decrease was observed in corneal density in the 0-2 mm ring (from 43.83 to 35.60, =0.043) and mean posterior Km (from -5.84 to -6.80, =0.005) in the first month. Corneal HOAs and all corneal densities improved at 6 months after DMEK ( < 0.05). All visual function parameters and corneal aberrations remained lower and higher, respectively, compared with healthy controls ( < 0.05). Corneal densities were comparable with controls at 6 months after DMEK ( > 0.05).

CONCLUSIONS

Patients undergoing DMEK present visual function improvement and a decrease in corneal density at 1 month after surgery. Decrease in corneal posterior HOAs can be observed at 6 months. However, visual function outcomes and corneal aberrations remained worse compared with healthy controls.

摘要

目的

评估深板层内皮角膜移植术(DMEK)后视觉功能和视觉质量参数的早期变化,并将结果与健康对照进行比较。

方法

对13例行DMEK手术的患者和14名对照者进行评估。所有受试者均接受视觉功能评估,包括明视觉和中视觉照明条件下的视力以及对比敏感度(CSV)测试(CSV 1000和佩利-罗布森测试)。使用Oculus Pentacam评估角膜参数。记录角膜平均角膜曲率(Km)、角膜密度值以及低阶和高阶像差(LOA和HOA)。在DMEK患者中,所有测试均在手术前以及手术后1个月和6个月进行。

结果

接受DMEK手术的患者,明视觉视力在术后1个月从0.59提高到0.31(P = 0.013),6个月时提高到0.13(P = 0.008);中视觉视力和所有对比敏感度值(CSV和佩利-罗布森测试)在第一个月均有显著改善(P < 0.005)。第一个月时,观察到0 - 2毫米环处的角膜密度显著降低(从43.83降至35.60,P = 0.043),平均后表面Km降低(从 - 5.84降至 - 6.80,P = 0.005)。DMEK术后6个月,角膜高阶像差和所有角膜密度均有改善(P < 0.05)。与健康对照相比,所有视觉功能参数和角膜像差分别仍较低和较高(P < 0.05)。DMEK术后6个月时角膜密度与对照相当(P > 0.05)。

结论

接受DMEK手术的患者在术后1个月视觉功能改善,角膜密度降低。术后6个月可观察到角膜后表面高阶像差降低。然而,与健康对照相比,视觉功能结果和角膜像差仍较差。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c661/6174748/1312ac361f48/JOPH2018-2012560.001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验