Suppr超能文献

一种用于医院放射性药房的基于溶剂萃取的紧凑型钼/锝发生器。

A compact solvent extraction based Mo/Tc generator for hospital radiopharmacy.

作者信息

Chattopadhyay Sankha, Saha Das Sujata, Barua Luna, Pal Asit Kumar, Kumar Umesh, Alam Md Nayer, Hudait Arup Kumar, Banerjee Sharmila

机构信息

Radiopharmaceuticals Lab., Regional Centre, Board of Radiation & Isotope Technology (BRIT), VECC, 1/AF, Bidhan Nagar, Kolkata 700064, India.

Radiopharmaceuticals Lab., Regional Centre, Board of Radiation & Isotope Technology (BRIT), VECC, 1/AF, Bidhan Nagar, Kolkata 700064, India.

出版信息

Appl Radiat Isot. 2019 Jan;143:41-46. doi: 10.1016/j.apradiso.2018.10.017. Epub 2018 Oct 18.

Abstract

A compact and portable Mo-Tc generator based on solvent-extraction, mimic to the conventional Mo-Tc alumina column generator is much-needed commodity for use in hospital radiopharmacy setup. The present study includes the development of a portable, simple and low cost Mo/Tc-generator based on MEK solvent extraction technique to obtain a very high concentration of no-carrier added (nca) Tc solution, where low specific activity Mo source is obtained through Mo(n, γ)Mo reaction in a research reactor. The unit is intended for operation under the conditions of medical radiological laboratories. Technical trials showed that the mean time of preparation of sodium [Tc] pertechnetate radiopharmaceutical did not exceed 15 min. The quality and yield of Tc-pertechnetate is upto the mark for formulation of radiopharmaceuticals.

摘要

一种基于溶剂萃取的紧凑型便携式钼-锝发生器,类似于传统的钼-锝氧化铝柱发生器,是医院放射性药物制备中急需的设备。本研究包括开发一种基于甲乙酮溶剂萃取技术的便携式、简单且低成本的钼/锝发生器,以获得非常高浓度的无载体添加(nca)锝溶液,其中低比活度钼源是通过在研究堆中利用钼(n,γ)钼反应获得的。该装置旨在在医学放射实验室的条件下运行。技术试验表明,高锝酸钠放射性药物的平均制备时间不超过15分钟。高锝酸盐的质量和产率符合放射性药物制剂的标准。

相似文献

4
99Mo/(99m)Tc separation: an assessment of technology options.99Mo/(99m)Tc 分离:技术方案评估。
Nucl Med Biol. 2013 Feb;40(2):167-76. doi: 10.1016/j.nucmedbio.2012.10.005. Epub 2012 Nov 9.