Suppr超能文献

健康受试者的盲点模拟

Scotoma Simulation in Healthy Subjects.

作者信息

Klee Sascha, Link Dietmar, Sinzinger Stefan, Haueisen Jens

机构信息

Department of Optoelectrophysiological Engineering, Technische Universität Ilmenau, Ilmenau, Germany.

Department of Mechanical Engineering, Technische Universität Ilmenau, Ilmenau, Germany.

出版信息

Optom Vis Sci. 2018 Dec;95(12):1120-1128. doi: 10.1097/OPX.0000000000001310.

Abstract

SIGNIFICANCE

This article shows a successful concept for simulating central scotoma, which is associated with age-related macular degeneration (AMD), in healthy subjects by an induced dark spot at the retina using occlusive contact lenses. The new concept includes a control mechanism to adjust the scotoma size through controlling pupil size without medication. Therefore, a miniaturized full-field adaptation device was used.

PURPOSE

The aim of this study was to design a novel concept to simulate AMD scotoma in healthy subjects using occlusive contact lenses.

METHODS

To define an optimal set of lens parameters, we constructed an optical model and considered both the anatomical pupil diameter and the opaque central zone diameter of the contact lens. To adjust the scotoma size, we built a miniaturized full-field adaptation device. We demonstrate the validity of this novel concept by functional measurements of visual fields using automated threshold perimetry. Finally, we conducted a perception study including two tasks, consisting of pictograms and letters. The stimuli were presented at different eccentricities and magnifications.

RESULTS

The visual fields of all 10 volunteers exhibited absolute scotomas. The loss of contrast sensitivity ranged within 27 and 36 dB (P < .05), and the scotoma localizations were nearly centered to the macula (mean variation, 2.0 ± 4.8° horizontally; 3.5 ± 4.7° vertically). The eccentric perception of letters showed the largest numbers of correctly identified stimuli. The perception of pictograms showed significantly reduced numbers (P < .0001) and revealed a dependency on magnification. The results suggest that best perception is possible for magnified stimuli near the scotoma.

CONCLUSIONS

We demonstrated that the creation of an absolute simulated AMD scotoma is possible using occlusive contact lenses combined with a miniaturized full-field adaptation device.

摘要

意义

本文展示了一种通过使用闭塞性隐形眼镜在视网膜上诱导出暗点,从而在健康受试者中模拟与年龄相关性黄斑变性(AMD)相关的中心暗点的成功概念。这个新概念包括一种无需药物通过控制瞳孔大小来调整暗点大小的控制机制。因此,使用了一种小型化的全视野适应装置。

目的

本研究的目的是设计一种使用闭塞性隐形眼镜在健康受试者中模拟AMD暗点的新概念。

方法

为了确定一组最佳的镜片参数,我们构建了一个光学模型,并考虑了隐形眼镜的解剖学瞳孔直径和不透明中心区直径。为了调整暗点大小,我们构建了一个小型化的全视野适应装置。我们通过使用自动阈值视野计进行视野功能测量来证明这一新概念的有效性。最后,我们进行了一项感知研究,包括两项任务,由象形图和字母组成。刺激在不同的偏心度和放大倍数下呈现。

结果

所有10名志愿者的视野均出现绝对暗点。对比敏感度损失范围在27至36 dB之间(P <.05),暗点定位几乎以黄斑为中心(水平平均变化为2.0±4.8°;垂直平均变化为3.5±4.7°)。字母的偏心感知显示正确识别的刺激数量最多。象形图的感知显示数量显著减少(P <.0001),并显示出对放大倍数的依赖性。结果表明,对于暗点附近放大的刺激,最佳感知是可能的。

结论

我们证明了使用闭塞性隐形眼镜结合小型化的全视野适应装置来创建绝对模拟AMD暗点是可行的。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5268/6266299/abe5e16f50ca/opx-95-1120-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验