Department of Electronic and Electrical Engineering, University of Bath, Claverton Down, Bath, BA2 7AY, UK.
Centre for Biosensors, Bioelectronics and Biodevices, University of Bath, Claverton Down, Bath, BA2 7AY, UK.
Sci Rep. 2018 Nov 20;8(1):17129. doi: 10.1038/s41598-018-35471-8.
Currently, the diagnosis of many diseases relies on laboratory-based immunoassays (ELISA, Western Blot), which are laborious, time-consuming and expensive. To address these limitations, we report a wash-free and label-free electrochemical immunoassay for rapid measurements of protein biomarkers in blood samples. This immunosensor employs a unique detection scheme based on electrochemical-chemical (EC) redox cycling for signal amplification combined with an affinity-based protein quantification strategy. All of the reagents required for this assay are dried and stored on a stacked membrane assembly, consisting of a Vivid Plasma Separation membrane and two cellulose membranes situated above the sensor, enabling excellent stability at room temperature for up to 2 months. Proof of concept was carried out by performing measurements of Plasmodium falciparum histidine-rich protein 2 (PfHRP2) in whole blood samples, which could be detected from 100 ng/mL to 100 µg/mL with excellent specificity and reproducibility. Each measurement requires only two liquid dispensing steps and can completed in 5 min, making this diagnostic platform promising for point-of-care testing in resource-limited settings.
目前,许多疾病的诊断依赖于基于实验室的免疫分析(ELISA、Western Blot),这些方法繁琐、耗时且昂贵。为了解决这些限制,我们报告了一种免洗和无标记的电化学免疫分析方法,用于快速测量血液样本中的蛋白质生物标志物。该免疫传感器采用基于电化学-化学(EC)氧化还原循环的独特检测方案进行信号放大,结合基于亲和力的蛋白质定量策略。该测定所需的所有试剂都干燥并储存在堆叠的膜组件上,该组件由 Vivid Plasma Separation 膜和位于传感器上方的两个纤维素膜组成,在室温下可稳定保存长达 2 个月。通过在全血样本中进行疟原虫富组氨酸蛋白 2(PfHRP2)的测量来验证概念,该方法可以从 100ng/mL 到 100μg/mL 进行检测,具有出色的特异性和重现性。每次测量仅需要两个液体分配步骤,并且可以在 5 分钟内完成,这使得该诊断平台有望在资源有限的环境中用于即时护理测试。