Abstract

The main effect of ionizing radiation on the eyes is the onset of posterior cortical and subcapsular cataracts. Recent studies have raised questions about the mechanism of ocular damage and the threshold dose for the onset of such effects. Currently, operators may be exposed to ionizing radiation during surgical procedures. It has been estimated that urologists can be exposed to an annual dose close to or above 20 mSv/year. The aim of our study was to evaluate the frequency of cataracts in a group of professional radiological operators to verify their possible association with the radiation dose to the crystalline lens and the tasks performed. The records of 73 health workers exposed to ionizing radiation were reviewed. The average annual dose to the crystalline lens, the number of years of exposure, and the presence of radiation-compatible opacities were assessed for all operators. Lenticular opacities were observed in 16.4% of subjects. The presence of alterations was associated with exposure doses below 10 mSv and > 10 years' experience in fluoroscopically guided procedures. Based on our results, protection of the crystalline lens against exposure to ionizing radiation by means of goggles is recommended. In addition, examination of the lens via slit lamp examination is recommended for all operators involved in interventional procedures with the current levels of radiation exposure.

摘要

电离辐射对眼睛的主要影响是后囊下皮质性白内障的发生。最近的研究对眼部损伤机制以及此类效应发生的阈值剂量提出了疑问。目前,手术过程中操作人员可能会受到电离辐射。据估计,泌尿外科医生每年可能受到接近或超过20毫希沃特/年的剂量照射。我们研究的目的是评估一组专业放射操作人员中白内障的发生频率,以验证其与晶状体辐射剂量及所执行任务之间的可能关联。回顾了73名暴露于电离辐射的卫生工作者的记录。评估了所有操作人员晶状体的年均剂量、暴露年限以及是否存在与辐射相关的混浊。16.4%的受试者观察到晶状体混浊。晶状体改变的存在与低于10毫希沃特的暴露剂量以及在荧光镜引导操作中超过10年的经验有关。根据我们的研究结果,建议通过护目镜保护晶状体免受电离辐射。此外,对于所有参与当前辐射暴露水平下介入操作的操作人员,建议通过裂隙灯检查对晶状体进行检查。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验