Departement of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussels (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium.
Departement of Imaging R&D, GE Healthcare Life Sciences, Amersham, Buckinghamshire, England.
Sci Rep. 2018 Nov 30;8(1):17493. doi: 10.1038/s41598-018-35918-y.
The study objective is to investigate the impact of a wide range of contrast media (CM) iodine concentrations on CT enhancement at constant total iodine dose (TID) and iodine delivery rate (IDR). Seven injection protocols, based on different iodine concentrations ranging from 120 to 370 mg I/mL, were assessed on 4 minipigs at a constant TID of 320 mg I/kg and IDR of 0.64 g I/s. Dynamic images were acquired on a clinical 64-slice MDCT scanner for 120 s with the abdominal aorta, vena cava inferior and liver parenchyma in the field-of-view. Maximal enhancement, time-to-peak and peak width were assessed. The enhancement curve characteristics were correlated with CM iodine concentration. In particular, CM with lower iodine concentrations yielded a significant increased maximal enhancement and peak width compared to the standard-of-care concentrations: e.g. in the aorta, 245 HU maximal enhancement and 9.2 s peak width with the 320 mg I/mL iodine concentration increased to 291 HU and 16.1 s with 160 mg I/mL. When maintaining a constant TID and IDR, by compensating injection rate and volume, injection of a CM with reduced iodine concentration results in a diagnostically beneficial higher maximal enhancement and longer enhancement peak duration.
本研究旨在探讨在恒定总碘剂量(TID)和碘输送率(IDR)下,广泛的对比剂(CM)碘浓度对 CT 增强的影响。在 4 只小型猪上,以 320 mg I/kg 的恒定 TID 和 0.64 g I/s 的 IDR 为基础,评估了七种基于从 120 至 370 mg I/mL 不同碘浓度的注射方案。在视野内采集了腹部主动脉、下腔静脉和肝实质的 120 s 动态图像。评估了最大增强、达峰时间和峰值宽度。将增强曲线特征与 CM 碘浓度相关联。特别是,与标准护理浓度相比,较低碘浓度的 CM 产生了显著增加的最大增强和峰值宽度:例如,在主动脉中,320mg I/mL 碘浓度下的最大增强为 245 HU,达峰时间为 9.2 s,而在 160mg I/mL 碘浓度下,最大增强为 291 HU,达峰时间为 16.1 s。当保持恒定的 TID 和 IDR 时,通过补偿注射速率和体积,注射低碘浓度的 CM 可产生具有诊断益处的更高的最大增强和更长的增强峰值持续时间。