Department of Chemistry, Faculty of Science , Kasetsart University , Bangkok 10900 , Thailand.
Institute of Molecular Biosciences , Mahidol University , Bangkok , Nakhon Pathom 73170 , Thailand.
ACS Sens. 2019 Jan 25;4(1):69-75. doi: 10.1021/acssensors.8b00885. Epub 2019 Jan 9.
Zika virus (ZIKV) is a flavivirus that was first identified in 1947. Initially, the virus was of little concern for health authorities given there were very few casualties among those suffering an infection. As such, only limited studies were performed on ZIKV. Recently, the viral infection has been linked to microcephaly in infants, which has prompted a dramatic increase in scientific interest in ZIKV research, including methods to allow for rapid virus identification. In this work we report the development of a new type of ZIKV electrochemical biosensor based on surface imprinted polymers and graphene oxide composites. The biosensor was used to detect ZIKV by measuring changes in the electrical signal with changing virus concentrations in buffer and serum using standard electrochemical techniques. The detection limit of our method is similar to the detection limit of the real-time quantitative reverse transcription PCR method.
Zika 病毒(ZIKV)是一种黄病毒,于 1947 年首次被发现。最初,由于感染该病毒的患者很少有死亡病例,因此卫生当局对该病毒的关注程度较低。因此,对 ZIKV 的研究也非常有限。最近,该病毒感染与婴儿小头畸形有关,这促使人们对 ZIKV 研究产生了浓厚的兴趣,包括用于快速鉴定病毒的方法。在这项工作中,我们报告了一种基于表面印迹聚合物和氧化石墨烯复合材料的新型 ZIKV 电化学生物传感器的开发。该生物传感器通过使用标准电化学技术,在缓冲液和血清中随着病毒浓度的变化测量电信号的变化,来检测 ZIKV。我们的方法的检测限与实时定量逆转录聚合酶链反应方法的检测限相似。