Suppr超能文献

OptoJump Next 系统测量优秀竞走运动员时间值的可靠性。

Reliability of the OptoJump Next System for Measuring Temporal Values in Elite Racewalking.

机构信息

Carnegie School of Sport, Leeds Beckett University, Leeds, United Kingdom.

出版信息

J Strength Cond Res. 2019 Dec;33(12):3438-3443. doi: 10.1519/JSC.0000000000003008.

Abstract

Hanley, B and Tucker, CB. Reliability of the OptoJump Next system for measuring temporal values in elite racewalking. J Strength Cond Res 33(12): 3438-3443, 2019-Racewalking is an Olympic event where athletes are not permitted a visible loss of contact, with the result that competitors try to minimize flight times. The accuracy of measurements taken during testing is dependent on valid and reliable systems to determine temporal values. The aim of the study was to compare different methodologies used to measure contact and flight times in overground and treadmill racewalking. Eighteen racewalkers completed overground and instrumented treadmill trials at 5 speeds, during which flight and contact times were measured using the OptoJump Next photocell system (1,000 Hz), high-speed videography (500 Hz), and force plates (1,000 Hz). Results from OptoJump Next were extracted using 5 settings based on the number of light-emitting diodes (LEDs) activated (GaitIn_GaitOut) and annotated as 0_0, 1_1, 2_2, 3_3, and 4_4. Regarding flight time measurements for the overground condition, the 2_2 LED setting had the best 95% confidence interval (95% CI) for intraclass correlation coefficient (ICC) (0.978-0.988), the least bias (0.000 seconds), and the lowest random error (RE) (0.008 seconds). For the treadmill condition, the 0_0 LED setting had the best 95% CI for ICC (0.890-0.957), the least bias (0.004 seconds), and the lowest RE (0.017 seconds). Although high-speed videography also provided highly reliable results, the equally reliable and quicker availability of results using OptoJump Next is beneficial in laboratory-based testing. Coaches and researches are advised to alter the system's LED settings as appropriate and to report these settings with their findings.

摘要

韩利和塔克,CB。OptoJump Next 系统测量精英竞走时间值的可靠性。J 力量与条件研究 33(12):3438-3443,2019-竞走是奥运会项目,运动员不允许可见的接触损失,因此参赛者试图尽量减少飞行时间。测试期间测量的准确性取决于确定时间值的有效和可靠系统。该研究的目的是比较在地面和跑步机上测量竞走接触和飞行时间的不同方法。18 名竞走运动员在 5 种速度下完成了地面和仪器化跑步机试验,在此期间使用 OptoJump Next 光电管系统(1000 Hz)、高速摄像(500 Hz)和测力板(1000 Hz)测量飞行和接触时间。OptoJump Next 的结果使用基于激活的发光二极管 (LED) 数量的 5 种设置提取(GaitIn_GaitOut),并标注为 0_0、1_1、2_2、3_3 和 4_4。对于地面条件下的飞行时间测量,2_2 LED 设置具有最佳的 95%置信区间(95%CI)的组内相关系数(ICC)(0.978-0.988)、最小偏差(0.000 秒)和最低随机误差(RE)(0.008 秒)。对于跑步机条件,0_0 LED 设置具有最佳的 95%CI ICC(0.890-0.957)、最小偏差(0.004 秒)和最低 RE(0.017 秒)。尽管高速摄像也提供了高度可靠的结果,但 OptoJump Next 更快、同样可靠地获得结果在实验室测试中是有益的。建议教练和研究人员根据需要调整系统的 LED 设置,并在他们的发现中报告这些设置。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验