Department of Cornea and Refractive Surgery, Institute of Ophthalmology "Conde de Valenciana", Mexico City, Mexico.
Department of Cornea and Refractive Surgery, Institute of Ophthalmology "Conde de Valenciana", Mexico City, Mexico.
J Cataract Refract Surg. 2019 Apr;45(4):519-522. doi: 10.1016/j.jcrs.2018.09.032. Epub 2019 Jan 25.
The implantable collamer lens (ICL) is a widely used posterior chamber phakic intraocular lens that achieves excellent refractive results. Nonetheless, serious postoperative complications related to inadequate vault have been previously reported. Therefore, lens exchange is advised when the vault is out of the recommended ranges. This article presents a case with persistent low vault after lens exchange in which no clinical evidence of crystalline lens opacity or decrease in uncorrected distance visual acuity has been identified during the 6-year clinical follow-up performed to date. Therefore, this suggests that clinical follow-up could be an appropriate approach for patients presenting with low vault, especially those who are older than 40 years and have a history of lens exchange.
可植入Collamer 透镜(ICL)是一种广泛使用的后房有晶状体眼人工晶状体,可获得出色的屈光效果。尽管如此,先前已有报道与拱高不足相关的严重术后并发症。因此,当拱高超出推荐范围时,建议进行晶状体置换。本文介绍了一例晶状体置换后持续低拱高的病例,在迄今为止进行的 6 年临床随访中,未发现晶状体混浊或未矫正远视力下降的临床证据。因此,这表明对于出现低拱高的患者,临床随访可能是一种合适的方法,特别是对于年龄大于 40 岁且有晶状体置换史的患者。