Suppr超能文献

虚拟现实髋关节镜模拟训练器的验证。

Validation of a Virtual Reality-Based Hip Arthroscopy Simulator.

机构信息

Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.

Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.

出版信息

Arthroscopy. 2019 Mar;35(3):789-795. doi: 10.1016/j.arthro.2018.10.131. Epub 2019 Feb 4.

Abstract

PURPOSE

To assess construct and face validity of a novel virtual reality-based hip arthroscopy simulator using the previously validated Arthroscopic Surgery Skills Evaluation Tool (ASSET), metric parameters, and a questionnaire.

METHODS

Metric parameters including task completion time, camera path, and grasper path were recorded, and the ASSET score was used to assess construct validity. Face validity was evaluated using a questionnaire.

RESULTS

Nine hip arthroscopy experts, of whom the majority performed more than 200 procedures (age, 48 ± 7.3; range, 38-61 years; 8 men, 1 woman), and 33 nonexperts (age, 33 ± 7.9; range, 26-62 years; 25 men, 8 women) performed 3 individual tasks on a virtual reality-based arthroscopy simulator of a left hip. The ASSET global rating scale showed a statistically significant difference between the hip arthroscopy expert and the nonexpert group, indicating strong construct validity (25.0 in the expert group, range, 17-34, versus 15.30 in the nonexpert group, range, 8-30 [P < .001], respectively). This also applied to most metric parameters recorded by the simulator. The simulator also demonstrated high face validity. The overall impression in terms of realism was graded "completely realistic" by 17% and "close to realistic" by 62% of participants.

CONCLUSIONS

The tested simulator demonstrated high construct and face validity.

CLINICAL RELEVANCE

This study demonstrates the construct and face validity of a novel hip arthroscopy simulator. The device proved to be an adequate model for the simulation of some arthroscopic procedures of the hip.

摘要

目的

使用先前经过验证的关节镜手术技能评估工具(Arthroscopic Surgery Skills Evaluation Tool,ASSET)、度量参数和问卷,评估一种新的基于虚拟现实的髋关节镜模拟器的构建和表面有效性。

方法

记录度量参数,包括任务完成时间、摄像头路径和抓握器路径,并使用 ASSET 评分评估构建有效性。使用问卷评估表面有效性。

结果

9 名髋关节镜专家(大多数人完成了超过 200 例手术;年龄 48 ± 7.3 岁;范围 38-61 岁;8 名男性,1 名女性)和 33 名非专家(年龄 33 ± 7.9 岁;范围 26-62 岁;25 名男性,8 名女性)在一个基于虚拟现实的左髋关节关节镜模拟器上完成了 3 项单独的任务。ASSET 整体评分量表显示,髋关节镜专家组和非专家组之间存在统计学显著差异,表明具有很强的构建有效性(专家组 25.0,范围 17-34,而非专家组 15.30,范围 8-30 [P <.001])。这也适用于模拟器记录的大多数度量参数。模拟器还表现出很高的表面有效性。在现实感方面,17%的参与者给予“完全逼真”的总体印象,62%的参与者给予“接近逼真”的总体印象。

结论

经过测试的模拟器具有较高的构建和表面有效性。

临床相关性

本研究证明了一种新型髋关节镜模拟器的构建和表面有效性。该设备被证明是模拟髋关节一些关节镜手术的合适模型。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验