Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants.

作者信息

Triches Diego Fernandes, Alonso Fernando Rizzo, Mezzomo Luis André, Schneider Danilo Renato, Villarinho Eduardo Aydos, Rockenbach Maria Ivete, Teixeira Eduardo Rolim, Shinkai Rosemary Sadami

机构信息

Postgraduate Program in Dentistry, Pontifical Catholic University of Rio Grande do Sul (PUCRS), Dental School, Avenida Ipiranga, 6681 - Prédio 6, Porto Alegre, RS, 90619-900, Brazil.

Postgraduate Program in Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil.

出版信息

Int J Implant Dent. 2019 Feb 11;5(1):9. doi: 10.1186/s40729-019-0158-6.

Abstract

BACKGROUND

This study assessed the relationship between insertion torque and bone quality evaluated during surgery and in preoperative computed tomographic (CT) images analyzed either visually or by rescaled mean gray values (MGVs). The study also tested the correlation between the clinical and radiographic measures of bone quality.

METHODS

The consecutive sample was composed of 45 short implants (4.1 × 6 mm) placed in the posterior region of 20 patients. Intra-surgical tactile bone quality, based on the classification of bone types by Lekholm and Zarb, and insertion torque were recorded during the implant placement. Visual bone quality and normalized MGV were assessed in standardized axial, coronal, and sagittal sections of preoperative CT images. Data were analyzed by ANOVA and Spearman correlation (alpha = 0.05).

RESULTS

Insertion torque was associated with all assessment methods of bone quality (tactile, CT visual, MGV). A moderate correlation was found among all methods of bone quality, except for CT visual assessment and tactile evaluation. MGVs varied as a function of arch, dental region, insertion torque, and bone types.

CONCLUSIONS

The results suggest that bone quality measures affect primary stability as recorded by insertion torque, and the assessment methods are consistently related.

摘要

背景

本研究评估了手术过程中评估的植入扭矩与骨质量之间的关系,以及在术前计算机断层扫描(CT)图像中通过视觉或重新缩放的平均灰度值(MGV)分析的骨质量之间的关系。该研究还测试了骨质量的临床测量与影像学测量之间的相关性。

方法

连续样本由放置在20例患者后部区域的45颗短种植体(4.1×6mm)组成。在种植体植入过程中,根据Lekholm和Zarb的骨类型分类记录手术中的触觉骨质量和植入扭矩。在术前CT图像的标准化轴向、冠状和矢状切片中评估视觉骨质量和标准化MGV。数据通过方差分析和Spearman相关性分析(α=0.05)。

结果

植入扭矩与骨质量的所有评估方法(触觉、CT视觉、MGV)相关。除CT视觉评估和触觉评估外,所有骨质量评估方法之间均存在中度相关性。MGV随牙弓、牙区、植入扭矩和骨类型而变化。

结论

结果表明,骨质量测量会影响植入扭矩记录的初始稳定性,并且评估方法之间存在一致的相关性。