In this study, a multiplex amplification system including 47 autosomal InDels, 2 Y-chromosome InDels, and the sex-determining marker (Amelogenin) was developed with six fluorescent dyes labeling. These InDels were selected from the previous study based on a series of criteria (0.3 < MAF < 0.5, HET > 0.4, etc). The system was designated the AGCU InDel 50 kit and was validated in a series of studies, including a degradation study; tests for sensitivity, species specificity, reproducibility, stability, applicability to case samples, balance of peak height, and PCR conditions; and a population study. The results showed that AGCU InDel 50 kit was quite sensitive, specific, stable in several PCR conditions or exposure to PCR inhibitors, especially against degradation. 74 case samples and 50 paternity cases with STR mutation events were tested using PowerPlex 21 System, AGCU InDel 50 kit, and Investigator DIPplex kit, and the results showed that the ratio of loci detected with the developed kit were close to Investigator DIPplex kit, but considerably higher than PowerPlex 21 System for case samples containing low amounts of degraded DNA. As for 50 paternity cases, no mutation was observed in any InDels locus, and the CPIs based on 47 autosomal InDels contained in the AGCU InDel 50 kit were all higher than those based on 30 InDels contained in Investigator® DIPplex kit, except 3 cases. In the population study, 203 unrelated individuals from the Guangdong Han population were detected using the AGCU InDel 50 kit, and the values of combined power of discrimination and combined power of exclusion were 0.999 999 999 999 999 and 0.9997, respectively. Thus, AGCU InDel 50 kit is suitable for individual identification and as a supplemental tool for paternity testing. It is reproducible, accurate and robust for forensic applications and human genetic studies.
在这项研究中,开发了一种多重扩增系统,包括 47 个常染色体 InDels、2 个 Y 染色体 InDels 和性别决定标记(Amelogenin),使用 6 种荧光染料进行标记。这些 InDels 是根据一系列标准(0.3<MAF<0.5,HET>0.4 等)从之前的研究中选择的。该系统被命名为 AGCU InDel 50 试剂盒,并在一系列研究中得到了验证,包括降解研究;灵敏度、物种特异性、重现性、稳定性、对案例样本的适用性、峰高平衡和 PCR 条件的测试;以及人群研究。结果表明,AGCU InDel 50 试剂盒非常敏感、特异、在几种 PCR 条件下或暴露于 PCR 抑制剂下稳定,特别是对降解有抵抗力。使用 PowerPlex 21 系统、AGCU InDel 50 试剂盒和 Investigator DIPplex 试剂盒对 74 个案例样本和 50 个亲子鉴定案例中的 STR 突变事件进行了测试,结果表明,与 Investigator DIPplex 试剂盒相比,开发的试剂盒检测到的基因座比例接近,但对于含有低量降解 DNA 的案例样本,其比例明显高于 PowerPlex 21 系统。对于 50 个亲子鉴定案例,没有观察到任何 InDels 基因座发生突变,并且基于 AGCU InDel 50 试剂盒中包含的 47 个常染色体 InDels 的 CPIs 均高于基于 Investigator®DIPplex 试剂盒中包含的 30 个 InDels 的 CPIs,除了 3 个案例。在人群研究中,使用 AGCU InDel 50 试剂盒对来自广东汉族的 203 个无关个体进行了检测,联合判别力和联合排除力的值分别为 0.99999999999999999 999 和 0.9997。因此,AGCU InDel 50 试剂盒适用于个体识别,也可作为亲子鉴定的补充工具。它在法医应用和人类遗传研究中具有可重复性、准确性和稳健性。