Suppr超能文献

Tissue composition effect on dose distribution in radiotherapy with a 6 MV photon beam of a medical linac.

作者信息

Ghorbani Mahdi, Noghreiyan Atefeh Vejdani, Tabatabaei Zahra Sadat, Pakravan Delaram, Davenport David

机构信息

Department of Biomedical Engineering and Medical Physics, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

出版信息

J Cancer Res Ther. 2019 Jan-Mar;15(1):237-244. doi: 10.4103/jcrt.JCRT_706_16.

Abstract

AIM

The aim of this study is to evaluate soft-tissue composition effect on dose distribution for various soft tissues in radiotherapy with a 6 MV photon beam of a medical linac.

BACKGROUND

The compositions of various soft tissues are different which could affect dose calculations.

MATERIALS AND METHODS

A phantom and Siemens Primus linear accelerator were simulated using MCNPX Monte Carlo code. In a homogeneous cubic phantom, six types of soft tissue and three types of tissue-equivalent materials were defined separately. The soft tissues were muscle (skeletal), adipose tissue, blood (whole), breast tissue, soft tissue (9-component), and soft tissue (4-component). The tissue-equivalent materials included water, A-150 tissue equivalent plastic and perspex. Photon dose relative to dose in 9-component soft tissue at various depths on the beam's central axis was determined for the 6 MV photon beam. The relative dose was also calculated and compared for various MCNPX tallies including *F8, F6, and *F4.

RESULTS

The results of the relative photon dose in various materials relative to dose in 9-component soft tissue using different tallies are reported in the form of tabulated data. Minor differences between dose distributions in various soft tissues and tissue-equivalent materials were observed. The results from F6 and F4 were practically the same but differ with the *F8 tally.

CONCLUSIONS

Based on the calculations performed, the differences in dose distributions in various soft tissues and tissue-equivalent materials are minor but they could be corrected in radiotherapy calculations to upgrade the accuracy of the dosimetric calculations.

摘要

相似文献

1
Tissue composition effect on dose distribution in radiotherapy with a 6 MV photon beam of a medical linac.
J Cancer Res Ther. 2019 Jan-Mar;15(1):237-244. doi: 10.4103/jcrt.JCRT_706_16.
2
Effect of tissue composition on dose distribution in electron beam radiotherapy.
J Biomed Phys Eng. 2015 Mar 4;5(1):15-24. eCollection 2015 Mar.
3
Monte Carlo photon beam modeling and commissioning for radiotherapy dose calculation algorithm.
Phys Med. 2014 Nov;30(7):833-7. doi: 10.1016/j.ejmp.2014.05.007. Epub 2014 Jun 16.
4
Effect of various dental restorations on dose distribution of 6 MV photon beam.
J Cancer Res Ther. 2017 Jul-Sep;13(3):538-543. doi: 10.4103/0973-1482.187245.
5
Monte Carlo simulation of the photon beam characteristics from medical linear accelerators.
Radiat Prot Dosimetry. 2006;119(1-4):510-3. doi: 10.1093/rpd/nci636. Epub 2006 Apr 27.
8
Dosimetric verification of small fields in the lung using lung-equivalent polymer gel and Monte Carlo simulation.
J Cancer Res Ther. 2018 Jan-Mar;14(2):278-286. doi: 10.4103/0973-1482.191040.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验